RVI70E-011K2R61N-00512 Explosion-Proof Encoder Custom Replacement Solution
We supply a custom replacement for the RVI70E-011K2R61N-00512 explosion-proof encoder. This solution is designed for 1:1 compatibility with the original model, covering both electrical parameters and mechanical dimensions. With a production cycle of around 10 working days, customers benefit from dependable supply and efficient delivery. The replacement encoder has already proven successful in global markets such as Southeast Asia, the Middle East, Russia, and South America.
The RVI70E-011K2R61N-00512 encoder provides incremental output at 512 pulses, making it suitable for applications requiring medium-resolution signal feedback. Its explosion-proof enclosure guarantees safe operation in environments with a risk of ignition from gas or dust. Combined with strong durability and reliable accuracy, it ensures consistent performance for long-term industrial use.
Replacement model image below.
Technical Data
Specification Category | Parameter | Details |
---|---|---|
General specifications | Detection type | photoelectric sampling |
Device type | Incremental rotary encoder | |
Pulse count | max. 5000 | |
Functional safety related parameters | MTTFₐ (Mean Time To Failure) | 140 a |
L₁₀ (Bearing life) | 1.6 E-9 at 3000 rpm | |
Electrical specifications | Operating voltage (UB) | 10 … 30 V DC or 5 V DC ± 5% (see "Output circuit" in ordering information) |
No-load supply current (IB) | max. 60 mA | |
Output type | push-pull, incremental or RS 422, incremental (see "Output circuit" in ordering information) | |
Voltage drop (UL) | < 4 V (push-pull, incremental) | |
Load current | max. per channel 35 mA (push-pull, short-circuit protected, reverse polarity protected)max. per channel 20 mA (RS 422, short-circuit protected, reverse polarity protected) | |
Output frequency | max. 200 kHz | |
Rise time | 250 ns | |
Phase position A to B | 90° ± 18° | |
Duty cycle | 1/2 ± 20% | |
De-energized delay (toff) | 250 ns | |
Connection | Cable | ∅10.2 mm, Radox 9 × 0.5 mm² |
Standard conformity | Degree of protection | DIN EN 60529, IP66DIN EN 60529, IP67 |
Climatic testing | DIN EN 60068-2-30, no moisture condensation | |
Emitted interference | EN IEC 61000-6-4:2019 | |
Noise immunity | EN IEC 61000-6-2:2019 | |
Shock resistance | DIN EN 60068-2-27: 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6: 10 g ... 2000 Hz |
Approvals and Certificates
Certification | Details |
---|---|
IECEx approval | Equipment protection level Gb: IECEx ZLM 14.0003XEquipment protection level Db: IECEx ZLM 14.0003X |
ATEX approval | Equipment protection level Gb: ZELM 14 ATEX 0619 XEquipment protection level Db: ZELM 14 ATEX 0619 X |
CCC approval | 2020323414001056 |
Hazardous Location | 19-AVBO-0390 and 19-AVBO-0391 |
KCC approval | (not specified) |
Ambient Conditions
Parameter | Details |
---|---|
Operating temperature | -40 … 70 °C (-40 … 158 °F) |
Storage temperature | -40 … 70 °C (-40 … 158 °F) |
Mechanical Specifications
Parameter | Details |
---|---|
Material | Combination 1:housing: anodized aluminumflange: stainless steel 1.4401 / AISI 316shaft: stainless steel 1.4401 / AISI 316Combination 2 (inox):housing: anodized aluminumflange: stainless steel 1.4401 / AISI 316shaft: stainless steel 1.4401 / AISI 316 |
Mass | approx. 1300 g (combination 1)approx. 1500 g (combination 2, anodized) |
Rotational speed | max. 6000 min⁻¹ |
Moment of inertia | 400 g·cm² |
Starting torque | < 5 mN·m |
Shaft load | Axial: 150 NRadial: 110 N |
General Information
Item | Details |
---|---|
Use in hazardous area | see Instruction manuals |