X700.M111402 Discontinued Encoder Custom Replacement Solution
The X700.M111402 is a discontinued encoder, and we provide a non-standard customized replacement solution to fully replicate the original specifications. The 1:1 design ensures complete mechanical and electrical compatibility, enabling direct installation without modifications. With a production cycle of 10–15 working days, this solution helps operators reduce downtime and maintain operational efficiency even when the original component is no longer available. It is an effective, cost-efficient alternative for wind energy and industrial applications requiring continuous and precise operation.
The X700.M111402 replacement encoder is a multiturn SSI absolute encoder utilizing optical sensing for high-precision measurement. It delivers reliable singleturn and multiturn feedback with resolutions suitable for turbine pitch and yaw control, automated machinery, and robotics. The encoder is equipped with a clamping flange for stable installation, electronic zero-point adjustment for simplified setup, and direction input for flexible signal integration. Optional incremental outputs provide extended functionality for complex control systems. Designed to resist magnetic interference, the encoder ensures stable and accurate performance even in electrically noisy industrial environments, supporting long-term reliability and precise position control.


Technical Data for X 700 - SSI - Multiturn Encoder
Technical data - electrical ratings
Parameter | Values |
---|---|
Voltage supply | 10...30 VDC5 VDC ±10 % |
Reverse polarity protection | Yes |
Consumption w/o load | ≤50 mA (24 VDC) |
Initializing time typ. | 20 ms after power on |
Interface | SSI |
Function | Multiturn |
Steps per revolution | 16384 / 14 bit |
Number of revolutions | 4096 / 12 bit |
Absolute accuracy | ±0.025 ° |
Sensing method | Optical |
Code | Gray or binary |
Code sequence | CW/CCW coded by connection |
Inputs | SSI clockControl signals UP/DOWN inv. and zero |
Output stages | SSI data: Linedriver RS422Diagnostic outputs push-pull |
Interference immunity | EN 61000-6-2 |
Emitted interference | EN 61000-6-4 |
Diagnostic function | Self-diagnosisMultiturn sensing |
Technical data - mechanical design
Parameter | Values |
---|---|
Size (flange) | ø70 mm |
Shaft type | ø10 mm solid shaft (clamping flange) |
Flange | Clamping flange |
Protection EN 60529 | IP 67 |
Operating speed | ≤6000 rpm (mechanical)≤6000 rpm (electric) |
Starting acceleration | ≤1000 U/s² |
Starting torque | ≤0.4 Nm (+25 °C) |
Admitted shaft load | ≤60 N axial≤50 N radial |
Material | Housing: stainless steelFlange: stainless steel |
Operating temperature | -20...+70 °C |
Relative humidity | 95 % non-condensing |
Resistance | EN 60068-2-6Vibration ±0.75 mm - 10-58 Hz, 10 g - 58-2000 HzEN 60068-2-27Shock 200 g, 6 ms |
Explosion protection | Ex II 2G Ex d IIC T6Ex II 2D |
Weight approx. | 1300 g |
Connection | Cable |