The FG40KK-1024G-90G-NG is a robust incremental encoder specifically developed for steel mills, metallurgy plants, and other heavy-duty environments. With 1024 pulses per revolution, it offers a balance of resolution and durability, making it suitable for general drive control and monitoring tasks.
This encoder is particularly valued for its ability to withstand harsh conditions such as constant vibration, high temperatures, and airborne contaminants. Its dependable performance ensures operators can trust it for continuous industrial processes.


Yet, in many cases, sourcing the FG40KK-1024G-90G-NG in a short timeframe proves difficult, resulting in downtime risks. To address this, we developed a custom replacement encoder that replicates the original’s specifications and installation design. This ensures quick and easy integration for industrial operators.
Our replacement encoders are engineered with durability and stability in mind, helping steel industry operators reduce downtime and extend the operational lifespan of their equipment. They serve as reliable alternatives where procurement delays would otherwise threaten production.
To further support our customers, we provide non-standard customization options, allowing tailored encoder production within a lead time of 15 working days. This enables industrial users to secure critical components quickly and efficiently.
Technical data
| Parameter | Value |
|---|---|
| Pulse rates | |
| Standard pulse rates | 500, 600, 1000, 1024, 1200, 2000, 2048, 2400, 2500 |
| Special pulse rates | 4000, 4096, 4800, 5000, 8192, 10000, 12000, 16000, 16384, 20000, 25000, 40000, 50000 (further pulse rates according to customer specification) |
| Connection data | |
| Supply voltage | 12 V … 30 V DC (optional: 5 V DC) For UL and CSA Class 2 supplied |
| No load-current | approx. 50 mA at 24 V |
| Outputs | Current limited, short-circuit proof push-pull line driver with integrated impedance adaptation for 30 to 140 Ω lines |
| Pulse height (HTL) | approx. as supply voltage, output saturation voltage < 0.4 V at Iₗ 30 mA |
| Output current | max. 150 mA at 24 V (observe derating) |
| Internal resistance | 75 Ω bei 24 V |
| Slew rate | 200 V/μs with C_L 100 pF |
| Duty cycle | 1:1 ± 3 % for standard pulse rates 1:1 ± 5 % for special pulse rates up to 25000 pulses |
| Square wave displacement 0°, 90° | 90° ± 3 % for standard pulse rates 90° ± 5 % for special pulse rates up to 25000 pulses |
| Max. frequency | 200 kHz, Higher max. frequency on request |
| Special output voltage 5V (TTL) | |
| Pulse height | 5V, RS422-compatible (TIA/EIA-Standard) |
| Supply voltage | 12 … 30 V DC (optional: 5 V DC) For UL and CSA Class 2 supplied |
| Alternative Connection Data (from image(1)_1.png) | |
| Supply voltage | 5 V … 30 V DC For UL and CSA Class 2 supplied |
| No load-current | Approx. 120 mA at 5 V, approx. 50 mA at 24 V |
| Output signals | 2 sinusoidal signals A and B each with inverted signals Reference pulse with inverted signal Signal amplitude 1 V pp / R_L = 120 Ω Error signal and inverted signal Signal amplitude 5V |
| Resolution | 1024 signal periods |
| Duty cycle | 1 ± 0.1 |
| Phase shift A, B | 90° ± 1° |