The RSA506 1078592-01 0-20mA absolute encoder is available through a customized replacement solution with a standard production lead time of 10 working days. This 1:1 replacement is designed to fully replicate the original encoder’s mechanical and electrical characteristics, ensuring seamless installation and compatibility with existing systems. It provides a reliable option for users seeking replacement, system modernization, or maintenance solutions when the original model is difficult to procure.
This encoder delivers precise position feedback via a 0-20mA analog output signal, providing stable and accurate performance even under challenging industrial conditions. Its rugged housing and high-quality internal components guarantee long-term durability against vibration, temperature changes, and heavy-duty use. Our replacement products are widely used in South America, Southeast Asia, the Middle East, Indonesia, and Russia, where they have earned recognition for reliability and consistent operation. The RSA506 1078592-01 replacement is ideal for process control, machinery automation, and motion feedback systems requiring accuracy and stability.
Replacement solution image


Encoder Technical Data and Configuration
1. Mechanical data
Parameter | Details |
---|---|
Operating temperature | -40°C...+80°C |
Ingress protection class [IEC 60529] | IP67 (IP56 at shaft inlet) |
Vibration [IEC 60068-2-64] | ≥300 m/s² |
Shock [IEC 60068-2-27] | ≥3000 m/s² |
Shaft load (axial/radial) | 50 N / 60 N |
Rotational speed max | 6000 rpm |
Shaft material | Stainless steel |
Cover material | Aluminium (Anodized) |
Weight | 300 g |
2. Encoder configuration
Parameter | Details |
---|---|
Type | RSA |
Model | 506 Singleturn |
Shaft type | Ø6 mm with partial flat |
Flange type | Clamping flange (GI-type) |
Power supply | 9-36 Vdc |
Output interface | Analogue 0-20 mA |
Absolute resolution | 10 bit (1024 positions per revolution) |
Connection type | Cable |
Connecting direction | Axial |
Cable length | 1.50 m |
Active angle | 180.0 degrees |
3. Electrical data
Parameter | Details |
---|---|
Polarity protected | Yes |
Short circuit protected outputs | Yes |
Current consumption (No load) | 40 mA at 24 Vdc (Max. 70 mA) |
Absolute accuracy | ±1 LSB |