We have developed an OEM replacement for the PVS14N-05MK2A030-0013 Profibus absolute encoder, providing full 1:1 compatibility with the original TR model. This replacement mirrors the original’s mechanical dimensions, mounting interface, and electrical connections, allowing for direct installation without any modifications. The standard delivery time is 15 working days, offering a dependable solution for maintenance, retrofits, or spare part requirements.
Our OEM replacement has already been successfully used in international markets, including the Middle East, Russia, Southeast Asia, Indonesia, and South America. It provides precise absolute position feedback, stable signal output, and durable construction for demanding industrial applications. This encoder ensures reliable performance and long-term operational stability in automated systems, servo drives, and heavy-duty machinery.
OEM Replacement image.


Technical data
| Parameter | Value |
|---|---|
| General specifications | |
| Detection type | photoelectric sampling |
| Electrical specifications | |
| Operating voltage | 10 … 30 V DC |
| No-load supply current | max. 190 mA |
| Output code | binary code |
| Code course (counting direction) | cw ascending/descending (programmable) |
| Interface | |
| Interface type | PROFIBUS |
| Protocol | DP |
| Single turn | 13 Bit |
| Transfer rate | 0.005 … 12 MBit/s |
| Standard conformity | PNO profile 3.062 |
| Connection | |
| Cable | ∅11.2 mm, 9-core, 2 m |
| Standard conformity | |
| Protection degree | DIN EN 60529, IP66 |
| Emitted interference | EN 61000-6-4:2007 |
| Noise immunity | EN 61000-6-2:2005 |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 … 2000 Hz |
| Ambient conditions | |
| Operating temperature | -40 … 55 °C (-40 … 131 °F) |
| Storage temperature | -40 … 70 °C (-40 … 158 °F) |
| Mechanical specifications | |
| Housing material | aluminum |
| Shaft material | stainless steel |
| Mass | approx. 3400 g |
| Rotational speed | max. 6000 min⁻¹ |
| Starting torque | ≤ 5 Ncm |
| Shaft load axial | 60 N |
| Shaft load radial | 80 N |
| Data for Ex-areas application | |
| EC-Type Examination Certificate | ZELM 02 ATEX 0078 X |
| Protection type | II 2G Ex nA IIC T6 Gb; II 2D Ex tD IIC 180 °C Db IP66 |
| Directive conformity | EN 60079-0:2012; EN 60079-1:2007; EN 60079-31:2009 |