For the model FG4L-1024-90G-50/125, we provide a 1:1 replacement solution produced through dedicated non-standard customization. The alternative unit is engineered to replicate the original encoder’s mechanical interface, mounting geometry, and electrical characteristics, ensuring complete compatibility. This approach is specifically designed to resolve sourcing challenges or situations where the original model becomes difficult to obtain. Installation is straightforward, as the replacement fits directly without any adjustments, delivering a seamless functional match.
Since this customized solution was introduced, it has been widely adopted by customers across multiple international markets. Users from regions such as the Middle East, Russia, Indonesia, Brazil, Southeast Asia, and Ukraine have successfully applied these tailor-made units in demanding industrial environments. The combination of reliable performance and a 15-working-day production timeline has made the offering especially attractive for clients seeking both precision and timely delivery.
Replacement solution image


Technical data
| Parameter | Value |
|---|---|
| Pulse rates | |
| Standard pulse rates | 500, 600, 1000, 1024, 1200, 2000, 2048, 2400, 2500 |
| Special pulse rates | 4000, 4096, 4800, 5000, 8192, 10000, 12000, 16000, 16384, 20000, 25000, 40000, 50000 (further pulse rates according to customer specification) |
| Connection data | |
| Supply voltage | 12 V … 30 V DC (optional: 5 V DC) For UL and CSA Class 2 supplied |
| No load-current | approx. 50 mA at 24 V |
| Outputs | Current limited, short-circuit proof push-pull line driver with integrated impedance adaptation for 30 to 140 Ω lines |
| Pulse height (HTL) | approx. as supply voltage, output saturation voltage < 0.4 V at Iₗ 30 mA |
| Output current | max. 150 mA at 24 V (observe derating) |
| Internal resistance | 75 Ω bei 24 V |
| Slew rate | 200 V/μs with C_L 100 pF |
| Duty cycle | 1:1 ± 3 % for standard pulse rates 1:1 ± 5 % for special pulse rates up to 25000 pulses |
| Square wave displacement 0°, 90° | 90° ± 3 % for standard pulse rates 90° ± 5 % for special pulse rates up to 25000 pulses |
| Max. frequency | 200 kHz, Higher max. frequency on request |
| Special output voltage 5V (TTL) | |
| Pulse height | 5V, RS422-compatible (TIA/EIA-Standard) |
| Supply voltage | 12 … 30 V DC (optional: 5 V DC) For UL and CSA Class 2 supplied |
| Alternative Connection Data (from image(1)_1.png) | |
| Supply voltage | 5 V … 30 V DC For UL and CSA Class 2 supplied |
| No load-current | Approx. 120 mA at 5 V, approx. 50 mA at 24 V |
| Output signals | 2 sinusoidal signals A and B each with inverted signals Reference pulse with inverted signal Signal amplitude 1 V pp / R_L = 120 Ω Error signal and inverted signal Signal amplitude 5V |
| Resolution | 1024 signal periods |
| Duty cycle | 1 ± 0.1 |
| Phase shift A, B | 90° ± 1° |