RVI70E-011K5R61I-02048 Incremental Explosion-Proof Encoder
En RVI70E-011K5R61I-02048 provides reliable incremental feedback for speed and position measurement in explosive atmospheres. Its explosion-proof certification ensures compliance with stringent safety standards, making it ideal for chemical processing, petrochemical, and offshore applications. The robust design maintains signal integrity even in extreme temperature and vibration conditions.
Equipped with a high-precision mechanical system, this encoder delivers consistent pulse output for advanced motion control. Its electrical shielding and resilient housing enhance immunity to interference, while the integrated torque rest prevents rotation relative to the shaft, ensuring accuracy over extended operational periods.
Imagen del modelo de sustitución a continuación.
Datos técnicos
Categoría de especificaciones | Parámetro | Detalles |
---|---|---|
Especificaciones generales | Tipo de detección | muestreo fotoeléctrico |
Tipo de dispositivo | Incremental rotary encoder | |
Pulse count | max. 5000 | |
Parámetros relacionados con la seguridad funcional | MTTFₐ (Mean Time To Failure) | 140 a |
L₁₀ (Bearing life) | 1.6 E-9 at 3000 rpm | |
Especificaciones eléctricas | Operating voltage (UB) | 10 … 30 V DC or 5 V DC ± 5% (see "Output circuit" in ordering information) |
No-load supply current (IB) | max. 60 mA | |
Output type | push-pull, incremental or RS 422, incremental (see "Output circuit" in ordering information) | |
Voltage drop (UL) | < 4 V (push-pull, incremental) | |
Load current | max. per channel 35 mA (push-pull, short-circuit protected, reverse polarity protected)max. per channel 20 mA (RS 422, short-circuit protected, reverse polarity protected) | |
Output frequency | max. 200 kHz | |
Rise time | 250 ns | |
Phase position A to B | 90° ± 18° | |
Ciclo de trabajo | 1/2 ± 20% | |
De-energized delay (toff) | 250 ns | |
Conexión | Cable | ∅10.2 mm, Radox 9 × 0.5 mm² |
Conformidad con las normas | Grado de protección | DIN EN 60529, IP66DIN EN 60529, IP67 |
Pruebas climáticas | DIN EN 60068-2-30, no moisture condensation | |
Emitted interference | EN IEC 61000-6-4:2019 | |
Noise immunity | EN IEC 61000-6-2:2019 | |
Resistencia a los golpes | DIN EN 60068-2-27: 100 g, 6 ms | |
Resistencia a las vibraciones | DIN EN 60068-2-6: 10 g ... 2000 Hz |
Homologaciones y certificados
Certificación | Detalles |
---|---|
IECEx approval | Equipment protection level Gb: IECEx ZLM 14.0003XEquipment protection level Db: IECEx ZLM 14.0003X |
ATEX approval | Equipment protection level Gb: ZELM 14 ATEX 0619 XEquipment protection level Db: ZELM 14 ATEX 0619 X |
CCC approval | 2020323414001056 |
Hazardous Location | 19-AVBO-0390 and 19-AVBO-0391 |
KCC approval | (not specified) |
Condiciones ambientales
Parámetro | Detalles |
---|---|
Temperatura de funcionamiento | -40 ... 70 °C (-40 ... 158 °F) |
Temperatura de almacenamiento | -40 ... 70 °C (-40 ... 158 °F) |
Especificaciones mecánicas
Parámetro | Detalles |
---|---|
Material | Combinación 1:housing: anodized aluminumflange: stainless steel 1.4401 / AISI 316shaft: stainless steel 1.4401 / AISI 316Combinación 2 (inox):housing: anodized aluminumflange: stainless steel 1.4401 / AISI 316shaft: stainless steel 1.4401 / AISI 316 |
Masa | approx. 1300 g (combination 1)approx. 1500 g (combination 2, anodized) |
Velocidad de rotación | máx. 6000 min-¹ |
Momento de inercia | 400 g·cm² |
Par de arranque | < 5 mN·m |
Carga del eje | Axial: 150 NRadial: 110 N |
General Information
Item | Detalles |
---|---|
Use in hazardous area | see Instruction manuals |