The FG40KK-2048G-90G-NG is a medium-resolution incremental encoder, providing 2048 pulses per revolution, commonly used in steel production lines, conveyor drives, and heavy-duty machinery. It delivers dependable signal feedback for precise speed and position monitoring.
This encoder is trusted for its durability in harsh operating conditions, functioning reliably even in high temperatures, constant vibration, and dusty environments typical of steel plants. Its rugged design makes it a go-to solution for demanding industries.
To address supply challenges, we developed a custom replacement encoder that replicates the original model’s key specifications and installation dimensions. This guarantees smooth replacement and eliminates downtime caused by system adaptation.


Our replacement solutions focus on reliability and consistency, ensuring uninterrupted operation in high-demand applications. Steel and metallurgy operators can count on our products to maintain production efficiency.
In addition to standard alternatives, we offer non-standard customization services, delivering solutions tailored to unique equipment requirements. This ensures compatibility with a wide variety of industrial setups.
To help operators overcome long delivery cycles, we provide custom encoders with a 15 working day lead time, ensuring timely supply and reducing the risk of costly production interruptions.
Technical data
| Parameter | Value |
|---|---|
| Pulse rates | |
| Standard pulse rates | 500, 600, 1000, 1024, 1200, 2000, 2048, 2400, 2500 |
| Special pulse rates | 4000, 4096, 4800, 5000, 8192, 10000, 12000, 16000, 16384, 20000, 25000, 40000, 50000 (further pulse rates according to customer specification) |
| Connection data | |
| Supply voltage | 12 V … 30 V DC (optional: 5 V DC) For UL and CSA Class 2 supplied |
| No load-current | approx. 50 mA at 24 V |
| Outputs | Current limited, short-circuit proof push-pull line driver with integrated impedance adaptation for 30 to 140 Ω lines |
| Pulse height (HTL) | approx. as supply voltage, output saturation voltage < 0.4 V at Iₗ 30 mA |
| Output current | max. 150 mA at 24 V (observe derating) |
| Internal resistance | 75 Ω bei 24 V |
| Slew rate | 200 V/μs with C_L 100 pF |
| Duty cycle | 1:1 ± 3 % for standard pulse rates 1:1 ± 5 % for special pulse rates up to 25000 pulses |
| Square wave displacement 0°, 90° | 90° ± 3 % for standard pulse rates 90° ± 5 % for special pulse rates up to 25000 pulses |
| Max. frequency | 200 kHz, Higher max. frequency on request |
| Special output voltage 5V (TTL) | |
| Pulse height | 5V, RS422-compatible (TIA/EIA-Standard) |
| Supply voltage | 12 … 30 V DC (optional: 5 V DC) For UL and CSA Class 2 supplied |
| Alternative Connection Data (from image(1)_1.png) | |
| Supply voltage | 5 V … 30 V DC For UL and CSA Class 2 supplied |
| No load-current | Approx. 120 mA at 5 V, approx. 50 mA at 24 V |
| Output signals | 2 sinusoidal signals A and B each with inverted signals Reference pulse with inverted signal Signal amplitude 1 V pp / R_L = 120 Ω Error signal and inverted signal Signal amplitude 5V |
| Resolution | 1024 signal periods |
| Duty cycle | 1 ± 0.1 |
| Phase shift A, B | 90° ± 1° |