X700.M121202 Discontinued Encoder Custom Replacement Solution
The X700.M121202 is a discontinued encoder model, and we offer a professional non-standard customized replacement solution. Our 1:1 replication process guarantees that all mechanical and electrical specifications of the replacement match the original unit, allowing plug-and-play installation. With a production cycle of 10–15 working days, operators can secure fast delivery, minimizing downtime and maintaining system reliability despite the discontinuation of the original model. This solution is ideal for applications that require precision and continuous operation while ensuring cost-effectiveness and reliability.
The X700.M121202 replacement encoder features SSI absolute output with multiturn capability and optical sensing, providing accurate position feedback for challenging applications such as wind turbines, industrial machinery, and automated production systems. It offers high-resolution singleturn and multiturn measurements, a clamping flange for secure mounting, and electronic zero-point adjustment for simplified commissioning. The counting direction input and optional incremental outputs allow flexible integration into complex control architectures. Built for maximum resistance against magnetic interference, the encoder delivers stable, long-term performance even in high electromagnetic noise environments, ensuring accuracy and safety for critical operations.


Technical Data for X 700 - SSI - Multiturn Encoder
Technical data - electrical ratings
Paramètres | Values |
---|---|
Voltage supply | 10...30 VDC5 VDC ±10 % |
Reverse polarity protection | Yes |
Consumption w/o load | ≤50 mA (24 VDC) |
Initializing time typ. | 20 ms after power on |
Interface | SSI |
Function | Multiturn |
Steps per revolution | 16384 / 14 bit |
Number of revolutions | 4096 / 12 bit |
Absolute accuracy | ±0.025 ° |
Sensing method | Optical |
Code | Gray or binary |
Code sequence | CW/CCW coded by connection |
Inputs | SSI clockControl signals UP/DOWN inv. and zero |
Output stages | SSI data: Linedriver RS422Diagnostic outputs push-pull |
Interference immunity | EN 61000-6-2 |
Emitted interference | EN 61000-6-4 |
Diagnostic function | Self-diagnosisMultiturn sensing |
Technical data - mechanical design
Paramètres | Values |
---|---|
Size (flange) | ø70 mm |
Shaft type | ø10 mm solid shaft (clamping flange) |
Flange | Clamping flange |
Protection EN 60529 | IP 67 |
Operating speed | ≤6000 rpm (mechanical)≤6000 rpm (electric) |
Starting acceleration | ≤1000 U/s² |
Starting torque | ≤0.4 Nm (+25 °C) |
Admitted shaft load | ≤60 N axial≤50 N radial |
Material | Housing: stainless steelFlange: stainless steel |
Operating temperature | -20...+70 °C |
Relative humidity | 95 % non-condensing |
Resistance | EN 60068-2-6Vibration ±0.75 mm - 10-58 Hz, 10 g - 58-2000 HzEN 60068-2-27Shock 200 g, 6 ms |
Explosion protection | Ex II 2G Ex d IIC T6Ex II 2D |
Weight approx. | 1300 g |
Connection | Cable |