We have developed a full replacement model for the EVM78E-011DRRPBN-1413 absolute encoder, offering complete mechanical and electrical compatibility with the original version. This replacement can be directly installed without any modification to the shaft, mounting, or connection interface. The standard delivery time is 15 working days, ensuring quick availability for both planned maintenance and urgent production requirements.
The EVM78E-011DRRPBN-1413 replacement unit provides precise absolute positioning and excellent resistance to environmental influences such as vibration, dust, and temperature variation. With its durable construction and advanced sensing technology, it ensures high stability and signal accuracy for continuous industrial use. This encoder is especially well-suited for motion control systems, automated production lines, and heavy-duty industrial drives.
Replacement solution image.


Technical Data
1. Basic Information
| Parameter | Value |
|---|---|
| Detection type | photoelectric sampling |
| Device type | Multiturn absolute rotary encoder |
2. Functional Safety Related Parameters
| Parameter | Value |
|---|---|
| MTTFₐ | 180 a |
| L₀ | 7.7 E-9 at 3000 rpm |
3. Electrical Specifications
| Parameter | Value |
|---|---|
| Operating voltage | U_B 10 … 30 V DC |
| No-load supply current | I₀ max. 270 mA at 10 V DC;max. 115 mA at 24 V DC |
| Time delay before availability | tᵥ < 250 ms |
| Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit |
| Output code | binary code |
| Code course (counting direction) | programmablecw ascending (clockwise rotation, code course ascending)cw descending (clockwise rotation, code course descending) |
4. Interface
| Parameter | Value |
|---|---|
| Interface type | PROFINET |
| Resolution | Single turn: up to 16 BitMultiturn: up to 14 BitOverall resolution: up to 30 Bit |
| Transfer rate | 100 MB/s |
| Cycle time | ≤ 1 ms (RT), ≤ 10 ms (RT) |
5. Connection
| Parameter | Value |
|---|---|
| Terminal compartment | see ordering information |
6. Standard Conformity
| Parameter | Value |
|---|---|
| Degree of protection | DIN EN 60529, IP66 |
| Climatic testing | DIN EN 60068-2-78, no moisture condensation |
| Emitted interference | EN 61000-6-4:2007/A1:2011 |
| Noise immunity | EN 61000-6-2:2005 |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 … 2000 Hz |
7. Approvals and Certificates
| Parameter | Value |
|---|---|
| IECEx approval | Equipment protection level Gb: IECEx ITS 15.0061X |
| ATEX approval | Equipment protection level Gb: ITS 15 ATEX 18372X |
8. Ambient Conditions
| Parameter | Value |
|---|---|
| Operating temperature | -40 … 70 °C (-40 … 158 °F) |
| Storage temperature | -40 … 85 °C (-40 … 185 °F) |