We have developed a dedicated replacement for the PVM14N-05MK2A500-1213 Profibus encoder, engineered to fully replicate the original TR model in both mechanical and electrical specifications. This 1:1 replacement allows for direct installation without modifications, offering a practical and reliable solution for maintenance, system upgrades, or spare part integration. The standard production and delivery time is 15 working days, ensuring minimal downtime in industrial operations.
This replacement encoder has already been applied successfully in multiple international markets, including the Middle East, Russia, Southeast Asia, Indonesia, and South America. It delivers precise and stable position feedback, robust signal performance, and durable construction capable of withstanding demanding industrial conditions. Ideal for automated machinery, motion control systems, and heavy-duty equipment, this encoder provides reliable operation and long-term accuracy, ensuring continued productivity in critical applications.
Replacement Solution image.


Technical data
| Parameter | Value |
|---|---|
| General specifications | |
| Detection type | photoelectric sampling |
| Device type | Multiturn absolute encoder |
| Electrical specifications | |
| Operating voltage | 10 … 30 V DC |
| No-load supply current | max. 190 mA |
| Linearity | ± 1 LSB |
| Output code | binary code |
| Code course (counting direction) | programmablecw ascending (clockwise rotation, code course ascending)cw descending (clockwise rotation, code course descending) |
| Interface | |
| Interface type | PROFIBUS |
| Resolution | Single turn: 13 BitMultiturn: 12 BitOverall resolution: 25 Bit |
| Transfer rate | 0.006 … 12 MB/s |
| Parameter | Value |
|---|---|
| Standard conformity & Connection | |
| Standard conformity | PNO profile 3.062 |
| Connection | ∅11.2 mm, 9-core, 2 m |
| Climatic and mechanical testing | |
| Degree of protection | DIN EN 60529, IP66 |
| Climatic testing | DIN EN 60068-2-3, no moisture condensation |
| Emitted interference | EN 61000-6-4:2007/A1:2011 |
| Noise immunity | EN 61000-6-2:2005 |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 … 2000 Hz |
| Ambient conditions | |
| Operating temperature | Gas Ex-area: -40 … 55 °C (-40 … 131 °F)Dust Ex-area: -30 … 55 °C (-22 … 131 °F) |
| Storage temperature | Gas Ex-area: -40 … 70 °C (-40 … 158 °F)Dust Ex-area: -30 … 70 °C (-22 … 158 °F) |
| Mechanical specifications | |
| Housing material | Aluminum, anodized |
| Flange material | Aluminum |
| Shaft material | Stainless steel |
| Mass | approx. 3400 g |
| Rotational speed | max. 6000 min⁻¹ |
| Moment of inertia | 400 gcm² |
| Starting torque | ≤ 5 Ncm |
| Shaft load axial | 60 N |
| Shaft load radial | 80 N |
| Data for hazardous areas application | |
| EU-Type Examination Certificate | ZELM 02 ATEX 0078 X |
| Marking | ⓞ II 2G Ex db IIC T6 Gbⓞ II 2D Ex tb IIIC T80°C Db |
| Directive conformity | EN 60079-20:2012 + A11:2013EN 60079-1:2014EN 60079-31:2014 |