The HOG163M DN 4096 I 55H7 is supplied as a through hollow shaft encoder replacement, engineered to replicate the original specifications exactly. All critical parameters, including shaft diameter, flange type, and signal output, are reproduced for seamless integration without any modification. A production timeline of 15 working days ensures consistent availability and helps maintain uninterrupted operations in industrial settings.
This encoder provides 4096 pulses per revolution, making it suitable for medium- to high-resolution applications such as factory automation, conveyor systems, and precision machinery. Its optical sensing technology delivers stable and accurate incremental feedback, while the insulated construction and HTL output allow long-distance cabling up to 350 meters. The combination of a durable housing and corrosion resistance ensures continuous, reliable operation in demanding industrial environments.
Reference Images


Technical data - electrical ratings
| Voltage supply | 9..30 VDC 5VDC+5% 9...26 VDC |
|---|---|
| Consumption w/o load | ≤100mA |
| Pulses per revolution | 250....2500 |
| Phase shift | 90°+20° |
| Duty cycle | 40...60% |
| Reference signal | Zero pulse,width 90° |
| Sensing method | Optical |
| Output frequency | S120 kHz |
| Output signals | K1,K2,KO+inverted |
| Output stages | HTL TTL/RS422 |
| Interference immunity | EN61000-6-2 |
| Emitted interference | EN61000-6-3 |
| Approval | CE UL approval/E217823 |
Technical data - mechanical design
| Protection EN 60529 | IP54 |
|---|---|
| Operating speed | S6000 rpm (mechanical) |
| Operating torque typ. | 15 Ncm |
| Rotor moment of inertia | 26.3 kgcm2(48) 13.5 kgcm2(75) |
| Material | Housing: aluminium alloy Shaft: stainless steel |
| Operating temperature | -40..+85℃ |
| Resistance | IEC 60068-2-6 Vibration 10g, 10-2000 Hz IEC 60068-2-27 Shock 100 g,6ms |
| Corrosion protection | IEC 60068-2-52 Salt mist for ambient conditions C4 according to ISO12944-2 |
| Explosion protection | I13G Ex ec IIC T4 Gc (gas) I1 3 D Extc II T10C Dc(dust) (only with option ATEX) |
| Connection | Terminal box 2x terminal box (with option M) |
| Weight approx. | 4.5kg (048) 3.2kg(075) 3.6 kg (o75 with option M) |