We manufacture a stainless-steel replacement unit for the RVI58X-032K1R61N-04096 encoder, ensuring 1:1 compatibility in both dimensions and performance specifications. Production is completed within 10–15 working days, enabling our customers to address delivery challenges quickly. By using stainless steel as the primary material, the replacement model offers enhanced protection against mechanical wear, vibration, and environmental corrosion, ensuring consistent performance across different industrial settings.
This encoder features a resolution of 4096 pulses per revolution, providing very high accuracy for demanding automation applications. Such resolution is essential for precise motor feedback, position tracking, and synchronization tasks in advanced manufacturing systems. The device offers six-channel incremental outputs, supporting versatile wiring configurations for PLCs and motion controllers. The encoder housing is designed with robust sealing, making it suitable for environments exposed to dust or occasional moisture. Furthermore, certification for use in hazardous zones 2 and 22 allows the encoder to be deployed safely in industries such as chemical processing, petroleum handling, and other explosion-prone areas. Its accuracy, combined with rugged construction, ensures long service life and dependable integration.
Technical Data
Specification Category
Parameter
Details
General specifications
Detection type
photoelectric sampling
Pulse count
max. 5000
Functional safety related parameters
MTTFₐ
140 a
L₁₀
70 E-9 at 6000 rpm
Diagnostic Coverage (DC)
0 %
Electrical specifications
Operating voltage (UB)
10 … 30 V DC
No-load supply current (I0)
max. 60 mA
Output
Output type
push-pull, incremental
Voltage drop (Ud)
< 3 V
Load current
max. per channel 40 mA, short-circuit protected (not with UB), reverse polarity protected
Output frequency
max. 200 kHz
Rise time
400 ns
Connection
Cable
∅7.8 mm, 6 x 2 x 0.14 mm², 1 m
Standard conformity
Degree of protection
DIN EN 60529, IP64
Climatic testing
DIN EN 60068-2-3, no moisture condensation
Emitted interference
EN 61000-6-4:2007/A1:2011
Noise immunity
EN 61000-6-2:2005
Shock resistance
DIN EN 60068-2-27, 100 g, 3 ms
Vibration resistance
DIN EN 60068-2-6, 10 g, 10 … 2000 Hz
Approvals and certificates
UL approval
cULus Listed, General Purpose, Class 2 Power Source
① II 3G Ex nA IIB T4 Ga X② II 3D Ex t IIIC T105°C Dc X
Certificate
PF 18 CERT 4775 X
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018, EN 60079-15:2010, EN 60079-31:2014
Disclaimer:
All content on this site is original unless otherwise noted. Copying, collecting, or publishing any material without our permission is prohibited. If any content infringes on copyright, please contact us.
GAMX12-0256-001:GAMX_12//5G59//00256//GPA030 Custom Replacement We offer a custom replacement for the GAMX12-0256-001 encoder, manufactured using non-standard customization to replicate the original model with 1:1 compatibility. Mechanical and electrical specifications are fully matched, ensuring seamless integration into existing equipment. With a production...
The 862209126-2048 768575-01 is a high-resolution incremental encoder engineered for demanding industrial environments where accurate and reliable motion feedback is essential. A fully compatible replacement solution is available, matching the original hollow shaft dimensions, mechanical interface, and electrical output specifications....
The FG40SS-1200G-90G-NG encoder was originally developed for demanding industrial automation applications requiring high accuracy and strong environmental resistance. We now offer a 1:1 customized replacement solution, perfectly matching the original mechanical interface, pulse resolution, and signal configuration. With a production...
The FGHJ40K-1024G-90G-NG/20P is a robust incremental encoder designed for heavy-duty industrial applications such as steel rolling mills, metallurgical automation systems, and high-load conveyor drives. With the original model increasingly difficult to source, we offer a fully customized 1:1 replacement solution....