GM400.Z67 SSI Penyandi Mutlak Custom Replacement Solution
We provide a customized 1:1 replacement solution for the GM400.Z67 encoder, ensuring complete compatibility with the original Baumer model. By using a non-standard customization approach, our products maintain identical dimensions and interface standards, allowing seamless installation. With a production cycle of just 10–15 working days, customers benefit from faster supply compared to long overseas lead times. This significantly reduces downtime in wind turbine operations, improving efficiency and reducing maintenance costs.
The GM400.Z67 replacement encoder delivers multiturn absolute position feedback through an SSI interface, applying optical scanning technology for consistent accuracy. It offers a resolution of up to 14 bits for singleturn measurement and 16 bits for multiturn, making it well-suited for precision control systems. The encoder features a clamping flange for reliable mounting, electronic zero-point adjustment for simplified calibration, and a direction input for flexible signal integration. Its strong resistance to magnetic interference ensures stable performance even in demanding wind turbine nacelles or heavy industrial environments where electromagnetic fields are present.
Replacement model real product photo.

Data Teknis
Electrical Ratings
Parameter | Values |
---|---|
Voltage supply | 10…30 VDC5 VDC ±10 % |
Reverse polarity protection | Yes (10…30 VDC) / No (5 VDC) |
Consumption w/o load | ≤50 mA (24 VDC)≤80 mA (5 VDC) |
Initializing time typ. | 20 ms after power on |
Interface | SSIIncremental A 90° B (optional) |
Function | Multiturn |
Steps per revolution | ≤16384 / 14 bit |
Number of revolutions | ≤65536 / 16 bit |
Absolute accuracy | ±0.025° |
Sensing method | Optical |
Code | Gray or binary |
Code sequence | CW/CCW coded by connection |
Inputs | SSI clock; Control signals UP/DOWN inv. and zero; SSI data outputs RS422 |
Output stages | Diagnostic: 1024, 2048 pulses + invertedIncremental output: 512, 1024, 2048 push-pull |
Interference immunity | EN 61000-6-2 |
Emitted interference | EN 61000-6-4 |
Diagnostic function | Self-diagnosis; Multiturn sensing |
Approval | UL approval / E63076 |
Mechanical Design
Parameter | Values |
---|---|
Size (flange) | ∅58 mm |
Optional |
---|
Stainless steel design |
Corrosion protection for offshore applications |
Parameter Category | Values |
---|---|
Shaft type | α10 design solid shaft |
Flange | Clamping flange |
Protection EN 60529 | IP 54 (without shaft seal)IP 65 (with shaft seal) |
Operating speed | ≤10000 rpm (mechanical)≤6000 rpm (electric) |
Angular acceleration | ≤25000 rad/s² (UB = 0 VDC)≤25000 rad/s² (UB = 10…30 VDC, 5 VDC) |
Starting torque | ≤0.015 Nm (+25 °C, IP 54)≤0.03 Nm (+25 °C, IP 65) |
Rotor moment of inertia | 20 g·cm² |
Admitted shaft load | ≤20 N axial≤40 N radial |
Material | Housing: aluminiumFlange: aluminium |
Suhu pengoperasian | -25…+85 °C-40…+85 °C (optional) |
Relative humidity | 95 % non-condensing |
Resistance | EN 60068-2-6Vibration ≤0.75 mm - 10 - 58 Hz, 10 g - 58 - 2000 HzEN 60068-2-27Shock 200 g, 6 ms |
Weight approx. | 400 g |
Koneksi | Connector M23, 12-pinConnector M12, 8-pinCable 1 m |