We have developed a fully compatible replacement encoder for the EVM78E-011DRRPBI-1413 model, designed to provide identical mechanical and electrical characteristics to the original TR product. This customized alternative ensures seamless installation and immediate system compatibility without any adjustments. The standard delivery time for this encoder replacement is 15 working days, making it ideal for minimizing downtime in industrial automation setups.
The EVM78E-011DRRPBI-1413 features high-resolution absolute signal output with excellent resistance to vibration and temperature variation. Engineered for reliability and precision, it performs exceptionally well in demanding motion control and rotary positioning systems. Its rugged construction and optimized sensor design ensure consistent performance and extended operational lifespan in factory and field environments.
Replacement solution image.


Technical Data
1. Basic Information
| Parameter | Value |
|---|---|
| Detection type | photoelectric sampling |
| Device type | Multiturn absolute rotary encoder |
2. Functional Safety Related Parameters
| Parameter | Value |
|---|---|
| MTTFₐ | 180 a |
| L₀ | 7.7 E-9 at 3000 rpm |
3. Electrical Specifications
| Parameter | Value |
|---|---|
| Operating voltage | U_B 10 … 30 V DC |
| No-load supply current | I₀ max. 270 mA at 10 V DC;max. 115 mA at 24 V DC |
| Time delay before availability | tᵥ < 250 ms |
| Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit |
| Output code | binary code |
| Code course (counting direction) | programmablecw ascending (clockwise rotation, code course ascending)cw descending (clockwise rotation, code course descending) |
4. Interface
| Parameter | Value |
|---|---|
| Interface type | PROFINET |
| Resolution | Single turn: up to 16 BitMultiturn: up to 14 BitOverall resolution: up to 30 Bit |
| Transfer rate | 100 MB/s |
| Cycle time | ≤ 1 ms (RT), ≤ 10 ms (RT) |
5. Connection
| Parameter | Value |
|---|---|
| Terminal compartment | see ordering information |
6. Standard Conformity
| Parameter | Value |
|---|---|
| Degree of protection | DIN EN 60529, IP66 |
| Climatic testing | DIN EN 60068-2-78, no moisture condensation |
| Emitted interference | EN 61000-6-4:2007/A1:2011 |
| Noise immunity | EN 61000-6-2:2005 |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 … 2000 Hz |
7. Approvals and Certificates
| Parameter | Value |
|---|---|
| IECEx approval | Equipment protection level Gb: IECEx ITS 15.0061X |
| ATEX approval | Equipment protection level Gb: ITS 15 ATEX 18372X |
8. Ambient Conditions
| Parameter | Value |
|---|---|
| Operating temperature | -40 … 70 °C (-40 … 158 °F) |
| Storage temperature | -40 … 85 °C (-40 … 185 °F) |