We provide a dedicated custom 1:1 replacement solution for the C-FG40KK-2048G-90G-NG-S encoder, developed specifically to resolve sourcing challenges, legacy equipment maintenance, and discontinued-model issues. This replacement is engineered according to the exact dimensions and performance characteristics of the original encoder. All mounting interfaces, shaft details, output signals, and electrical specifications are reproduced through non-standard customization, ensuring full compatibility with existing installation environments. Because the replacement follows a precise one-to-one configuration, customers can install it immediately without requiring structural modifications, software adjustments, or additional calibration procedures.
Since introducing this tailored replacement service, our customized encoders have been widely adopted across a variety of international markets. Users from the Middle East, Russia, Indonesia, Ukraine, Southeast Asia, and Brazil have successfully commissioned replacements to support critical machinery in steel production, automation lines, processing equipment, and other heavy-duty applications. Customers appreciate both the functional reliability of the customized units and our ability to keep the production cycle at approximately 15 working days, which minimizes downtime and allows maintenance teams to restore equipment operation quickly and efficiently.
Gambar solusi pengganti


Data teknis
| Parameter | Nilai |
|---|---|
| Denyut nadi | |
| Denyut nadi standar | 500, 600, 1000, 1024, 1200, 2000, 2048, 2400, 2500 |
| Denyut nadi khusus | 4000, 4096, 4800, 5000, 8192, 10000, 12000, 16000, 16384, 20000, 25000, 40000, 50000 (denyut nadi lebih lanjut sesuai dengan spesifikasi pelanggan) |
| Data koneksi | |
| Tegangan suplai | 12 V ... 30 V DC (opsional: 5 V DC) Untuk UL dan CSA Kelas 2 disediakan |
| Tidak ada arus beban | sekitar 50 mA pada 24 V |
| Keluaran | Driver jalur dorong-tarik arus terbatas dan tahan hubung singkat dengan adaptasi impedansi terintegrasi untuk jalur 30 hingga 140 Ω |
| Ketinggian pulsa (HTL) | kira-kira. sebagai tegangan suplai, tegangan saturasi keluaran <0,4 V pada Iₗ 30 mA |
| Arus keluaran | maks. 150 mA pada 24 V (amati penurunan daya) |
| Resistensi internal | 75 Ω bei 24 V |
| Tingkat pembunuhan | 200 V/μs dengan C_L 100 pF |
| Siklus tugas | 1:1 ± 3 % untuk denyut nadi standar 1:1 ± 5 % untuk denyut nadi khusus hingga 25.000 denyut |
| Perpindahan gelombang persegi 0°, 90° | 90° ± 3 % untuk denyut nadi standar 90° ± 5 % untuk denyut nadi khusus hingga 25.000 denyut |
| Maks. frekuensi | 200 kHz, frekuensi maksimal lebih tinggi berdasarkan permintaan |
| Tegangan output khusus 5V (TTL) | |
| Ketinggian denyut nadi | 5V, kompatibel dengan RS422 (Standar TIA/EIA) |
| Tegangan suplai | 12 ... 30 V DC (opsional: 5 V DC) Untuk UL dan CSA Kelas 2 yang disediakan |
| Data Koneksi Alternatif (dari gambar (1) _1.png) | |
| Tegangan suplai | 5 V ... 30 V DC Untuk UL dan CSA Kelas 2 disediakan |
| Tidak ada arus beban | Kira-kira 120 mA pada 5 V, kira-kira 50 mA pada 24 V |
| Sinyal keluaran | 2 sinyal sinusoidal A dan B masing-masing dengan sinyal terbalik Pulsa referensi dengan sinyal terbalik Amplitudo sinyal 1 V pp/R_L = 120 Ω Sinyal kesalahan dan sinyal terbalik Amplitudo sinyal 5V |
| Resolusi | 1024 periode sinyal |
| Siklus tugas | 1 ± 0.1 |
| Pergeseran fasa A, B | 90° ± 1° |