X700.M151202 Discontinued Encoder Custom Replacement Solution
The X700.M151202 is a discontinued encoder model, and we offer a professional non-standard customized replacement solution designed for seamless integration. Our 1:1 replication process ensures that all mechanical and electrical features match the original unit, allowing direct installation without any modifications. With production cycles of 10–15 working days, this solution minimizes downtime, provides rapid availability, and delivers a cost-effective alternative to sourcing obsolete components. This makes it suitable for operators of wind turbines, industrial machinery, and automated production systems who require high reliability and continuous operation.
The X700.M151202 replacement encoder is a multiturn SSI absolute encoder that employs optical sensing technology for accurate position feedback. It offers high-resolution singleturn and multiturn measurements, a clamping flange for secure mounting, and electronic zero-point adjustment for simple commissioning. Direction input and optional incremental outputs enhance system integration flexibility. Its construction provides strong resistance to magnetic interference, ensuring stable and reliable performance even in electrically noisy environments such as turbine nacelles, industrial drive systems, and heavy-duty automation equipment. The encoder delivers precise and dependable feedback, supporting long-term operational efficiency and safety in critical applications.


Technical Data for X 700 - SSI - Singleturn Encoder
Technical data - electrical ratings
Parametr | Values |
---|---|
Voltage supply | 10…30 VDC |
Reverse polarity protection | Yes |
Consumption w/o load | ≤50 mA (24 VDC) |
Initializing time typ. | 20 ms (after power on) |
Interface | SSI |
Function | Singleturn |
Steps per revolution | 16384 / 14 bit |
Absolute accuracy | ±0.025 ° |
Sensing method | Optical |
Code | Gray or binary |
Code sequence | CW/CCW coded by connection |
Inputs | SSI clockControl signals UP/DOWN inv. and zero |
Output stages | SSI data: Linedriver RS422Diagnostic outputs push-pull |
Interference immunity | EN 61000-6-2 |
Emitted interference | EN 61000-6-4 |
Diagnostic function | Self-diagnosis |
Technical data - mechanical design
Parametr | Values |
---|---|
Size (flange) | ø70 mm |
Shaft type | ø10 mm solid shaft (clamping flange) |
Flange | Clamping flange |
Protection EN 60529 | IP 67 |
Operating speed | ≤6000 rpm (mechanical)≤6000 rpm (electric) |
Starting acceleration | ≤1000 U/s² |
Starting torque | ≤0.4 Nm (+25 °C) |
Admitted shaft load | ≤60 N axial≤50 N radial |
Material | Housing: stainless steelFlange: stainless steel |
Operating temperature | -20…+70 °C |
Relative humidity | 95% non-condensing |
Resistance | EN 60068-2-6Vibration ±0.75 mm - 10-58 Hz, 10 g - 58-2000 HzEN 60068-2-27Shock 200 g, 6 ms |
Explosion protection | Ex II 2G Ex d IIC T6Ex II 2D |
Weight approx. | 1300 g |
Connection | Cable |