The HOG163M DN 1024 R 38H7 is offered as a customized HTL encoder replacement, engineered for complete 1:1 equivalence with the original unit. All key mechanical and electrical parameters, including flange type, shaft diameter, and output signal characteristics, are carefully matched to allow direct integration. The production cycle of 15 working days ensures that high-quality replacements are available without long delays, maintaining operational continuity in industrial applications.
This model delivers 1024 pulses per revolution, making it suitable for low- to medium-resolution automation and motor control systems. The HTL output supports long cable runs of up to 350 meters, ensuring reliable signal transmission in complex setups. Its hollow shaft configuration, optical sensing, and robust aluminum housing with corrosion protection provide durable, precise performance even in challenging operational environments. This makes it ideal for a wide range of industrial applications requiring dependable incremental feedback.
Reference Images


Technical data - electrical ratings
| Voltage supply | 9..30 VDC 5VDC+5% 9...26 VDC |
|---|---|
| Consumption w/o load | ≤100mA |
| Pulses per revolution | 250....2500 |
| Phase shift | 90°+20° |
| Duty cycle | 40...60% |
| Reference signal | Zero pulse,width 90° |
| Sensing method | Optical |
| Output frequency | S120 kHz |
| Output signals | K1,K2,KO+inverted |
| Output stages | HTL TTL/RS422 |
| Interference immunity | EN61000-6-2 |
| Emitted interference | EN61000-6-3 |
| Approval | CE UL approval/E217823 |
Technical data - mechanical design
| Protection EN 60529 | IP54 |
|---|---|
| Operating speed | S6000 rpm (mechanical) |
| Operating torque typ. | 15 Ncm |
| Rotor moment of inertia | 26.3 kgcm2(48) 13.5 kgcm2(75) |
| Material | Housing: aluminium alloy Shaft: stainless steel |
| Operating temperature | -40..+85℃ |
| Resistance | IEC 60068-2-6 Vibration 10g, 10-2000 Hz IEC 60068-2-27 Shock 100 g,6ms |
| Corrosion protection | IEC 60068-2-52 Salt mist for ambient conditions C4 according to ISO12944-2 |
| Explosion protection | I13G Ex ec IIC T4 Gc (gas) I1 3 D Extc II T10C Dc(dust) (only with option ATEX) |
| Connection | Terminal box 2x terminal box (with option M) |
| Weight approx. | 4.5kg (048) 3.2kg(075) 3.6 kg (o75 with option M) |