The ASS58N-F1AK1A0GN-0012 is a singleturn absolute encoder widely used in industrial automation systems where accuracy and signal reliability are critical. We offer a 1:1 replacement solution for this model, fully compatible in both mechanical and electrical specifications. The replacement encoder supports SSI communication and features a 58 mm compact housing, recessed hollow shaft, and high-speed RS422 interface for efficient data transfer.
With a 16-bit resolution design, it provides precise position detection with smooth signal response, ideal for robotics, packaging, and factory control environments. The microcontroller-based internal logic ensures consistent synchronization between the encoder and the control unit. Designed for direct shaft mounting without couplings, this encoder delivers easy installation and long-term stability even under heavy vibration.
Replacement solution image


Technical data
| Parameter | Value |
|---|---|
| General specifications | |
| Detection type | photoelectric sampling |
| Device type | Multiturn absolute encoder |
| Electrical specifications | |
| Operating voltage | 4.5 ... 30 V DC |
| No-load supply current | max. 180 mA |
| Time delay before availability | < 250 ms |
| Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0.5 LSB at 12 Bit |
| Output code | Gray code, Binary code |
| Code course (counting direction) | cw descending (clockwise rotation, code course descending) |
| Interface | |
| Interface type | SSI |
| Monoflop time | 20 ± 10 μs |
| Resolution | - Single turn: up to 16 Bit- Multiturn: 14 Bit- Overall resolution: up to 30 Bit |
| Transfer rate | 0.1 ... 2 MB/s |
| Voltage drop | V |
| Standard conformity | RS 422 |
| Input 1 | |
| Input type | Selection of counting direction (cw/ccw) |
| Signal voltage | - High: 4.5 ... 30 V- Low: 0 ... 2 V |
| Input current | < 6 mA |
| Switch-on delay | < 10 ms |
| Connection | |
| Connector | type 9416 (M23), 12-pin, type 9416L (M23), 12-pin |
| Cable | 67 mm, 6 × 2 × 0.14 mm², 1 m |
| Standard conformity | |
| Degree of protection | - DIN EN 60529, IP65 (without shaft seal)- DIN EN 60529, IP66/IP67 (with shaft seal) |
| Climatic testing | DIN EN 60068-2-3, no moisture condensation |
| Emitted interference | DIN EN 61000-6-4 |
| Noise immunity | DIN EN 61000-6-2 |
| Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms |