We have developed a high-precision replacement encoder for the EVM78E-012DRRPBI-1213 model, offering a fully compatible substitute to the original TR absolute encoder. The replacement product ensures a perfect mechanical fit and identical electrical characteristics, allowing users to install it directly without any modification. The standard delivery time for this encoder is 15 working days, supporting rapid response to equipment maintenance demands.
The EVM78E-012DRRPBI-1213 combines durable construction with precise absolute positioning technology, providing stable signal output and resistance to mechanical stress and vibration. Its optimized design enables reliable performance in automated systems, motion control machinery, and heavy-duty industrial applications. This encoder guarantees high operational reliability and long service life under challenging environmental conditions.
Replacement solution image.


Technical Data
1. Basic Information
| Parameter | Value |
|---|---|
| Detection type | photoelectric sampling |
| Device type | Multiturn absolute rotary encoder |
2. Functional Safety Related Parameters
| Parameter | Value |
|---|---|
| MTTFₐ | 180 a |
| L₀ | 7.7 E-9 at 3000 rpm |
3. Electrical Specifications
| Parameter | Value |
|---|---|
| Operating voltage | U_B 10 … 30 V DC |
| No-load supply current | I₀ max. 270 mA at 10 V DC;max. 115 mA at 24 V DC |
| Time delay before availability | tᵥ < 250 ms |
| Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit |
| Output code | binary code |
| Code course (counting direction) | programmablecw ascending (clockwise rotation, code course ascending)cw descending (clockwise rotation, code course descending) |
4. Interface
| Parameter | Value |
|---|---|
| Interface type | PROFINET |
| Resolution | Single turn: up to 16 BitMultiturn: up to 14 BitOverall resolution: up to 30 Bit |
| Transfer rate | 100 MB/s |
| Cycle time | ≤ 1 ms (RT), ≤ 10 ms (RT) |
5. Connection
| Parameter | Value |
|---|---|
| Terminal compartment | see ordering information |
6. Standard Conformity
| Parameter | Value |
|---|---|
| Degree of protection | DIN EN 60529, IP66 |
| Climatic testing | DIN EN 60068-2-78, no moisture condensation |
| Emitted interference | EN 61000-6-4:2007/A1:2011 |
| Noise immunity | EN 61000-6-2:2005 |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 … 2000 Hz |
7. Approvals and Certificates
| Parameter | Value |
|---|---|
| IECEx approval | Equipment protection level Gb: IECEx ITS 15.0061X |
| ATEX approval | Equipment protection level Gb: ITS 15 ATEX 18372X |
8. Ambient Conditions
| Parameter | Value |
|---|---|
| Operating temperature | -40 … 70 °C (-40 … 158 °F) |
| Storage temperature | -40 … 85 °C (-40 … 185 °F) |