We have developed an equivalent model to replace the PVM14N-05MK2A441-1213 Profibus encoder, providing full 1:1 mechanical and electrical compatibility with the original TR unit. This replacement allows direct installation without any modifications, offering a practical solution for maintenance, retrofits, and spare part needs. The standard delivery time is 15 working days, ensuring reliable and timely support for industrial systems.
This equivalent encoder has been successfully applied in various international markets, including the Middle East, Russia, Southeast Asia, Indonesia, and South America. It delivers stable and accurate position feedback, robust signal output, and durable construction suitable for demanding industrial environments. Designed for long-term reliability, this encoder is ideal for automated machinery, motion control systems, and heavy-duty equipment requiring consistent operation and high precision.
Equivalent Model image.


Technical data
| Parameter | Value |
|---|---|
| General specifications | |
| Detection type | photoelectric sampling |
| Device type | Multiturn absolute encoder |
| Electrical specifications | |
| Operating voltage | 10 … 30 V DC |
| No-load supply current | max. 190 mA |
| Linearity | ± 1 LSB |
| Output code | binary code |
| Code course (counting direction) | programmablecw ascending (clockwise rotation, code course ascending)cw descending (clockwise rotation, code course descending) |
| Interface | |
| Interface type | PROFIBUS |
| Resolution | Single turn: 13 BitMultiturn: 12 BitOverall resolution: 25 Bit |
| Transfer rate | 0.006 … 12 MB/s |
| Parameter | Value |
|---|---|
| Standard conformity & Connection | |
| Standard conformity | PNO profile 3.062 |
| Connection | ∅11.2 mm, 9-core, 2 m |
| Climatic and mechanical testing | |
| Degree of protection | DIN EN 60529, IP66 |
| Climatic testing | DIN EN 60068-2-3, no moisture condensation |
| Emitted interference | EN 61000-6-4:2007/A1:2011 |
| Noise immunity | EN 61000-6-2:2005 |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 … 2000 Hz |
| Ambient conditions | |
| Operating temperature | Gas Ex-area: -40 … 55 °C (-40 … 131 °F)Dust Ex-area: -30 … 55 °C (-22 … 131 °F) |
| Storage temperature | Gas Ex-area: -40 … 70 °C (-40 … 158 °F)Dust Ex-area: -30 … 70 °C (-22 … 158 °F) |
| Mechanical specifications | |
| Housing material | Aluminum, anodized |
| Flange material | Aluminum |
| Shaft material | Stainless steel |
| Mass | approx. 3400 g |
| Rotational speed | max. 6000 min⁻¹ |
| Moment of inertia | 400 gcm² |
| Starting torque | ≤ 5 Ncm |
| Shaft load axial | 60 N |
| Shaft load radial | 80 N |
| Data for hazardous areas application | |
| EU-Type Examination Certificate | ZELM 02 ATEX 0078 X |
| Marking | ⓞ II 2G Ex db IIC T6 Gbⓞ II 2D Ex tb IIIC T80°C Db |
| Directive conformity | EN 60079-20:2012 + A11:2013EN 60079-1:2014EN 60079-31:2014 |