RVI70E-011K2A61N-05000 Explosion-Proof Encoder Custom Replacement Solution
We offer a reliable replacement solution for the RVI70E-011K2A61N-05000 explosion-proof encoder. Fully compatible with the original product’s specifications and installation, it can be integrated directly without modification. The production time is around 10 working days, supporting customers with efficient supply schedules. Users in Russia, the Middle East, Southeast Asia, and South America already trust this replacement for demanding applications.
This encoder provides incremental output with a resolution of 5000 pulses, allowing precise position control in automation systems. It is designed with an explosion-proof enclosure, making it safe for deployment in environments with potential gas or dust ignition risks. Its durable construction ensures consistent feedback performance, even in heavy-duty applications where precision and compliance with safety standards are both essential.
Replacement model image below.
Teknik Veriler
Specification Category | Parametre | Detaylar |
---|---|---|
General specifications | Detection type | photoelectric sampling |
Device type | Incremental rotary encoder | |
Pulse count | max. 5000 | |
Functional safety related parameters | MTTFₐ (Mean Time To Failure) | 140 a |
L₁₀ (Bearing life) | 1.6 E-9 at 3000 rpm | |
Electrical specifications | Operating voltage (UB) | 10 … 30 V DC or 5 V DC ± 5% (see "Output circuit" in ordering information) |
No-load supply current (IB) | max. 60 mA | |
Output type | push-pull, incremental or RS 422, incremental (see "Output circuit" in ordering information) | |
Voltage drop (UL) | < 4 V (push-pull, incremental) | |
Load current | max. per channel 35 mA (push-pull, short-circuit protected, reverse polarity protected)max. per channel 20 mA (RS 422, short-circuit protected, reverse polarity protected) | |
Output frequency | max. 200 kHz | |
Rise time | 250 ns | |
Phase position A to B | 90° ± 18° | |
Duty cycle | 1/2 ± 20% | |
De-energized delay (toff) | 250 ns | |
Connection | Cable | ∅10.2 mm, Radox 9 × 0.5 mm² |
Standard conformity | Degree of protection | DIN EN 60529, IP66DIN EN 60529, IP67 |
Climatic testing | DIN EN 60068-2-30, no moisture condensation | |
Emitted interference | EN IEC 61000-6-4:2019 | |
Noise immunity | EN IEC 61000-6-2:2019 | |
Shock resistance | DIN EN 60068-2-27: 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6: 10 g ... 2000 Hz |
Approvals and Certificates
Certification | Detaylar |
---|---|
IECEx approval | Equipment protection level Gb: IECEx ZLM 14.0003XEquipment protection level Db: IECEx ZLM 14.0003X |
ATEX approval | Equipment protection level Gb: ZELM 14 ATEX 0619 XEquipment protection level Db: ZELM 14 ATEX 0619 X |
CCC approval | 2020323414001056 |
Hazardous Location | 19-AVBO-0390 and 19-AVBO-0391 |
KCC approval | (not specified) |
Ambient Conditions
Parametre | Detaylar |
---|---|
Operating temperature | -40 … 70 °C (-40 … 158 °F) |
Storage temperature | -40 … 70 °C (-40 … 158 °F) |
Mechanical Specifications
Parametre | Detaylar |
---|---|
Material | Combination 1:housing: anodized aluminumflange: stainless steel 1.4401 / AISI 316shaft: stainless steel 1.4401 / AISI 316Combination 2 (inox):housing: anodized aluminumflange: stainless steel 1.4401 / AISI 316shaft: stainless steel 1.4401 / AISI 316 |
Mass | approx. 1300 g (combination 1)approx. 1500 g (combination 2, anodized) |
Rotational speed | max. 6000 min⁻¹ |
Moment of inertia | 400 g·cm² |
Starting torque | < 5 mN·m |
Shaft load | Axial: 150 NRadial: 110 N |
General Information
Item | Detaylar |
---|---|
Use in hazardous area | see Instruction manuals |