X700.M141202 Discontinued Encoder Custom Replacement Solution
The X700.M141202 is a discontinued encoder, and we provide a non-standard customized replacement solution engineered to fully replicate the original specifications. Through a 1:1 custom design, this solution maintains mechanical and electrical compatibility, ensuring plug-and-play installation without adjustments. With a production cycle of 10–15 working days, our approach allows operators to maintain system uptime, minimize downtime, and avoid delays caused by the unavailability of discontinued components. This solution is ideal for critical applications where precise position feedback and operational continuity are essential.
The X700.M141202 replacement encoder utilizes SSI absolute output with multiturn capability and optical sensing technology to deliver high-precision position measurements. It achieves singleturn and multiturn resolutions suitable for wind energy control systems, industrial automation lines, and heavy machinery. The encoder is equipped with a clamping flange for robust installation, electronic zero-point adjustment for simplified setup, and a counting direction input for flexible integration. Optional incremental outputs allow additional functionality for complex control architectures. Built to resist magnetic interference, it maintains stable performance in environments with high electromagnetic exposure, ensuring reliable operation and long-term accuracy.


Technical Data for X 700 - SSI - Singleturn Encoder
Technical data - electrical ratings
Parametre | Values |
---|---|
Voltage supply | 10…30 VDC |
Reverse polarity protection | Yes |
Consumption w/o load | ≤50 mA (24 VDC) |
Initializing time typ. | 20 ms (after power on) |
Interface | SSI |
Function | Singleturn |
Steps per revolution | 16384 / 14 bit |
Absolute accuracy | ±0.025 ° |
Sensing method | Optical |
Code | Gray or binary |
Code sequence | CW/CCW coded by connection |
Inputs | SSI clockControl signals UP/DOWN inv. and zero |
Output stages | SSI data: Linedriver RS422Diagnostic outputs push-pull |
Interference immunity | EN 61000-6-2 |
Emitted interference | EN 61000-6-4 |
Diagnostic function | Self-diagnosis |
Technical data - mechanical design
Parametre | Values |
---|---|
Size (flange) | ø70 mm |
Shaft type | ø10 mm solid shaft (clamping flange) |
Flange | Clamping flange |
Protection EN 60529 | IP 67 |
Operating speed | ≤6000 rpm (mechanical)≤6000 rpm (electric) |
Starting acceleration | ≤1000 U/s² |
Starting torque | ≤0.4 Nm (+25 °C) |
Admitted shaft load | ≤60 N axial≤50 N radial |
Material | Housing: stainless steelFlange: stainless steel |
Operating temperature | -20…+70 °C |
Relative humidity | 95% non-condensing |
Resistance | EN 60068-2-6Vibration ±0.75 mm - 10-58 Hz, 10 g - 58-2000 HzEN 60068-2-27Shock 200 g, 6 ms |
Explosion protection | Ex II 2G Ex d IIC T6Ex II 2D |
Weight approx. | 1300 g |
Connection | Cable |