We have developed a direct replacement encoder for the EVS78E-011DRRPBN-0013 model, fully compatible with the original TR design. This replacement maintains identical mechanical and electrical specifications, allowing straightforward installation without system modifications. The standard delivery time is 15 working days, providing a reliable option for maintenance, retrofits, or spare part needs.
The EVS78E-011DRRPBN-0013 replacement encoder provides accurate absolute position feedback with consistent signal stability. Its robust construction and precision components ensure reliable performance in demanding industrial environments. Designed for motion control, automated machinery, and heavy-duty equipment, this encoder delivers high repeatability and long-term operational reliability.
Replacement solution image.


Technical Data
1. Basic Information
| Parameter | Value |
|---|---|
| Detection type | photoelectric sampling |
| Device type | Singleturn absolute rotary encoder |
2. Functional Safety Related Parameters
| Parameter | Value |
|---|---|
| MTTFₐ | 180 a |
| L₀ | 7.7 E-9 at 3000 rpm |
3. Electrical Specifications
| Parameter | Value |
|---|---|
| Operating voltage | U_B 10 … 30 V DC |
| No-load supply current | I₀ max. 270 mA at 10 V DC;max. 115 mA at 24 V DC |
| Time delay before availability | tᵥ < 250 ms |
| Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit |
| Output code | binary code |
| Code course (counting direction) | programmablecw ascending (clockwise rotation, code course ascending)cw descending (clockwise rotation, code course descending) |
4. Interface
| Parameter | Value |
|---|---|
| Interface type | PROFINET |
| Resolution | Single turn: up to 16 |
| Transfer rate | 100 MB/s |
| Cycle time | ≤ 1 ms (RT), ≤ 10 ms (RT) |
5. Connection
| Parameter | Value |
|---|---|
| Terminal compartment | see ordering information |
6. Standard Conformity
| Parameter | Value |
|---|---|
| Degree of protection | DIN EN 60529, IP66 |
| Climatic testing | DIN EN 60068-2-78, no moisture condensation |
| Emitted interference | EN 61000-6-4:2007/A1:2011 |
| Noise immunity | EN 61000-6-2:2005 |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 … 2000 Hz |
7. Approvals and Certificates
| Parameter | Value |
|---|---|
| IECEx approval | Equipment protection level Gb: IECEx ITS 15.0061X |
| ATEX approval | Equipment protection level Gb: ITS 15 ATEX 18372X |
8. Ambient Conditions
| Parameter | Value |
|---|---|
| Operating temperature | -40 … 70 °C (-40 … 158 °F) |
| Storage temperature | -40 … 85 °C (-40 … 185 °F) |