The 6FX2001-5FP12 Profibus-DP absolute encoder can be offered through a 1:1 customized replacement solution with a standard lead time of 10 working days. Our replacement model is engineered to replicate the mechanical and electrical properties of the original unit, including identical shaft type, flange size, and Profibus-DP interface, ensuring a direct and seamless installation. This allows end users to restore system operation without additional wiring or programming adjustments.
From a technical standpoint, this replacement encoder ensures precise position feedback and stable Profibus-DP communication, making it suitable for factory automation, robotics, and drive control applications. Its rugged structure and high signal integrity guarantee long-term stability even in harsh industrial conditions. Our products have been widely adopted across multiple regions—such as South America, Southeast Asia, the Middle East, Indonesia, and Russia—where they continue to demonstrate outstanding reliability and performance.
Replacement solution image


Mechanical Data
| Parameter | Value |
|---|---|
| Operating voltage | DC 10 … 30 V |
| Interface | PROFIBUS DP - V2 |
| Clock input | Differential line receiver according to EIA Standard RS - 485 |
| Data output | Differential line driver according to EIA Standard RS - 485 |
| Short - circuit strength | Yes |
| Transmission rate | 12 Mbit/s |
| Cable length up to the subsequent electronics, max. | Up to 93.75 kbit/s: 1200 mUp to 1.5 Mbit/s: 200 m |
| Connection | Terminal block with address selector switch and bus terminating resistor (with removable cover and cable glands, 3 units) |
| Resolution | 13 bit |
| Telegram | According to PNO encoder profile V4.1;Class 1, Class 2, Class 3, standard telegram 81 |
| Code type | Sampling: GrayTransmission: binary, PROFIBUS |
| Parameterizability | • Preset: Yes• Counting direction: Yes• Resolution per revolution: Any 1 … 8192• Total resolution: Any 1 … 8192• Speed signal: Yes• Limit switch: Yes• Clock synchronism: Yes• Slave - to - slave communication: Yes |
| Accuracy | ± 79'' (= ± 1 LSB at 8192 steps) |
| Friction torque (at ) | ≤ 0.1 |
| Starting torque (at ) | ≤ 0.01 |