We supply a precise 1:1 replacement for the ASS58N-F2AAARHGN-0013 singleturn absolute encoder, maintaining full compatibility with its original mechanical interface and SSI output parameters. Featuring a compact 58 mm housing and durable hollow shaft design, this encoder provides accurate and interference-free signal transmission at speeds up to 2 MBaud. Its hardware signal generation ensures consistent feedback and long operational stability, perfectly suited for high-performance automation applications.
Our replacement encoder solutions have been implemented globally across steel, automation, and heavy industry sectors. With strong performance in markets such as Southeast Asia, Indonesia, and Russia, these encoders offer a dependable alternative to discontinued or hard-to-find models. Users appreciate our technical precision, robust design, and ability to deliver consistent quality within short lead times.
Replacement solution image


Technical data
| Parameter | Value |
|---|---|
| General specifications | |
| Detection type | photoelectric sampling |
| Device type | Multiturn absolute encoder |
| Electrical specifications | |
| Operating voltage | 4.5 ... 30 V DC |
| No-load supply current | max. 180 mA |
| Time delay before availability | < 250 ms |
| Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0.5 LSB at 12 Bit |
| Output code | Gray code, Binary code |
| Code course (counting direction) | cw descending (clockwise rotation, code course descending) |
| Interface | |
| Interface type | SSI |
| Monoflop time | 20 ± 10 μs |
| Resolution | - Single turn: up to 16 Bit- Multiturn: 14 Bit- Overall resolution: up to 30 Bit |
| Transfer rate | 0.1 ... 2 MB/s |
| Voltage drop | V |
| Standard conformity | RS 422 |
| Input 1 | |
| Input type | Selection of counting direction (cw/ccw) |
| Signal voltage | - High: 4.5 ... 30 V- Low: 0 ... 2 V |
| Input current | < 6 mA |
| Switch-on delay | < 10 ms |
| Connection | |
| Connector | type 9416 (M23), 12-pin, type 9416L (M23), 12-pin |
| Cable | 67 mm, 6 × 2 × 0.14 mm², 1 m |
| Standard conformity | |
| Degree of protection | - DIN EN 60529, IP65 (without shaft seal)- DIN EN 60529, IP66/IP67 (with shaft seal) |
| Climatic testing | DIN EN 60068-2-3, no moisture condensation |
| Emitted interference | DIN EN 61000-6-4 |
| Noise immunity | DIN EN 61000-6-2 |
| Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms |