The ASS58N-F2AAARHGN-0016 is a singleturn SSI encoder for which we offer a complete OEM-compatible replacement solution. This model features a ∅58 mm industrial-grade housing and provides 16-bit resolution for precise position detection. Our replacement version maintains the same SSI communication protocol, electrical pin configuration, and mounting layout, ensuring smooth integration into existing control systems without modification.
Built for demanding industrial applications, this encoder delivers accurate data transfer, excellent mechanical strength, and long service life. Our SSI replacement encoders have been successfully used in steel mills, automated plants, and petrochemical facilities. They are trusted by customers in Southeast Asia, the Middle East, and South America for reliable operation and stable performance under harsh conditions.
Replacement solution image


Technical data
| Parameter | Value |
|---|---|
| General specifications | |
| Detection type | photoelectric sampling |
| Device type | Multiturn absolute encoder |
| Electrical specifications | |
| Operating voltage | 4.5 ... 30 V DC |
| No-load supply current | max. 180 mA |
| Time delay before availability | < 250 ms |
| Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0.5 LSB at 12 Bit |
| Output code | Gray code, Binary code |
| Code course (counting direction) | cw descending (clockwise rotation, code course descending) |
| Interface | |
| Interface type | SSI |
| Monoflop time | 20 ± 10 μs |
| Resolution | - Single turn: up to 16 Bit- Multiturn: 14 Bit- Overall resolution: up to 30 Bit |
| Transfer rate | 0.1 ... 2 MB/s |
| Voltage drop | V |
| Standard conformity | RS 422 |
| Input 1 | |
| Input type | Selection of counting direction (cw/ccw) |
| Signal voltage | - High: 4.5 ... 30 V- Low: 0 ... 2 V |
| Input current | < 6 mA |
| Switch-on delay | < 10 ms |
| Connection | |
| Connector | type 9416 (M23), 12-pin, type 9416L (M23), 12-pin |
| Cable | 67 mm, 6 × 2 × 0.14 mm², 1 m |
| Standard conformity | |
| Degree of protection | - DIN EN 60529, IP65 (without shaft seal)- DIN EN 60529, IP66/IP67 (with shaft seal) |
| Climatic testing | DIN EN 60068-2-3, no moisture condensation |
| Emitted interference | DIN EN 61000-6-4 |
| Noise immunity | DIN EN 61000-6-2 |
| Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms |