The FG40K-2000G-90G-NG is a well-recognized incremental encoder in the steel and metallurgy industry, built to provide accurate feedback and dependable performance. With a resolution of 2000 pulses per revolution, it delivers the balance of precision and durability needed for drive monitoring and conveyor line synchronization.
Its value lies in its robust mechanical construction and ability to function under harsh industrial conditions such as high temperatures, dust, and constant vibration. This makes it especially useful for heavy-duty applications where reliability cannot be compromised.


For many steel plants, however, sourcing this encoder within a short timeframe can be a serious challenge. To resolve this issue, we developed a custom replacement solution that mirrors the original in both electrical and mechanical aspects. This ensures direct compatibility and eliminates downtime caused by system adjustments.
Our replacement encoders are engineered for longevity and stability, providing operators with confidence that their production processes will remain uninterrupted. By integrating our solutions, companies in the metallurgy sector can reduce equipment risks and maintain high productivity levels.
To further support urgent procurement needs, we accept non-standard customization orders for the FG40K-2000G-90G-NG. Our average lead time is 15 working days, offering fast delivery and dependable performance for steel industry operators facing tight schedules.
Technical data
| Parameter | Value |
|---|---|
| Pulse rates | |
| Standard pulse rates | 500, 600, 1000, 1024, 1200, 2000, 2048, 2400, 2500 |
| Special pulse rates | 4000, 4096, 4800, 5000, 8192, 10000, 12000, 16000, 16384, 20000, 25000, 40000, 50000 (further pulse rates according to customer specification) |
| Connection data | |
| Supply voltage | 12 V … 30 V DC (optional: 5 V DC) For UL and CSA Class 2 supplied |
| No load-current | approx. 50 mA at 24 V |
| Outputs | Current limited, short-circuit proof push-pull line driver with integrated impedance adaptation for 30 to 140 Ω lines |
| Pulse height (HTL) | approx. as supply voltage, output saturation voltage < 0.4 V at Iₗ 30 mA |
| Output current | max. 150 mA at 24 V (observe derating) |
| Internal resistance | 75 Ω bei 24 V |
| Slew rate | 200 V/μs with C_L 100 pF |
| Duty cycle | 1:1 ± 3 % for standard pulse rates 1:1 ± 5 % for special pulse rates up to 25000 pulses |
| Square wave displacement 0°, 90° | 90° ± 3 % for standard pulse rates 90° ± 5 % for special pulse rates up to 25000 pulses |
| Max. frequency | 200 kHz, Higher max. frequency on request |
| Special output voltage 5V (TTL) | |
| Pulse height | 5V, RS422-compatible (TIA/EIA-Standard) |
| Supply voltage | 12 … 30 V DC (optional: 5 V DC) For UL and CSA Class 2 supplied |
| Alternative Connection Data (from image(1)_1.png) | |
| Supply voltage | 5 V … 30 V DC For UL and CSA Class 2 supplied |
| No load-current | Approx. 120 mA at 5 V, approx. 50 mA at 24 V |
| Output signals | 2 sinusoidal signals A and B each with inverted signals Reference pulse with inverted signal Signal amplitude 1 V pp / R_L = 120 Ω Error signal and inverted signal Signal amplitude 5V |
| Resolution | 1024 signal periods |
| Duty cycle | 1 ± 0.1 |
| Phase shift A, B | 90° ± 1° |