The 6FX2001-5WP24 Profibus-DP absolute encoder can be supplied as a 1:1 customized replacement solution, with a standard lead time of 10 working days. Our replacement unit is designed to perfectly match the original encoder’s mechanical interface, shaft configuration, and Profibus-DP communication specifications, ensuring smooth installation and immediate system compatibility. This plug-and-play design minimizes downtime and eliminates the need for software or wiring modifications.
From a technical perspective, this encoder provides precise absolute position measurement and stable Profibus-DP communication, making it highly suitable for CNC machinery, servo systems, and automated production lines. Its robust structure and long-lasting components ensure reliable performance even in harsh industrial environments. Our replacement encoders have been successfully utilized in South America, Southeast Asia, the Middle East, Indonesia, and Russia, consistently delivering excellent results in demanding applications.
Replacement solution image


Mechanical Data
| Parameter | Value |
|---|---|
| Operating voltage | DC 10 … 30 V |
| Interface | PROFIBUS DP - V2 |
| Clock input | Differential line receiver according to EIA Standard RS - 485 |
| Data output | Differential line driver according to EIA Standard RS - 485 |
| Short - circuit strength | Yes |
| Transmission rate | 12 Mbit/s |
| Cable length up to the subsequent electronics, max. | Up to 93.75 kbit/s: 1200 mUp to 1.5 Mbit/s: 200 m |
| Connection | Terminal block with address selector switch and bus terminating resistor (with removable cover and cable glands, 3 units) |
| Resolution | 27 bit |
| Telegram | According to PNO encoder profile V4.1;Class 1, Class 2, Class 3, standard telegram 81 |
| Code type | Sampling: GrayTransmission: binary, PROFIBUS |
| Parameterizability | • Preset: Yes• Counting direction: Yes• Resolution per revolution: Any 1 … 8192• Total resolution: Any 1 … 8192• Speed signal: Yes• Limit switch: Yes• Clock synchronism: Yes• Slave - to - slave communication: Yes |
| Accuracy | ± 79'' (= ± 1 LSB at 8192 steps) |
| Friction torque (at ) | ≤ 0.1 |
| Starting torque (at ) | ≤ 0.01 |