We have developed an equivalent model to replace the PVS14N-05MK2A671-0013 Profibus absolute encoder, offering full 1:1 compatibility with the original TR unit. The replacement matches the original’s mechanical dimensions, mounting interface, and electrical specifications, allowing seamless integration without modifications. The standard delivery time for this encoder is 15 working days, providing a reliable solution for maintenance, retrofits, and spare part requirements.
Our equivalent encoder has been successfully applied in various international markets, including the Middle East, Russia, Southeast Asia, Indonesia, and South America. It provides accurate absolute position feedback, stable signal output, and durable construction for demanding industrial environments. This model is suitable for motion control, automated machinery, and heavy-duty applications where precision and reliability are critical.
Equivalent Model image.


Technical data
| Parameter | Value |
|---|---|
| General specifications | |
| Detection type | photoelectric sampling |
| Electrical specifications | |
| Operating voltage | 10 … 30 V DC |
| No-load supply current | max. 190 mA |
| Output code | binary code |
| Code course (counting direction) | cw ascending/descending (programmable) |
| Interface | |
| Interface type | PROFIBUS |
| Protocol | DP |
| Single turn | 13 Bit |
| Transfer rate | 0.005 … 12 MBit/s |
| Standard conformity | PNO profile 3.062 |
| Connection | |
| Cable | ∅11.2 mm, 9-core, 2 m |
| Standard conformity | |
| Protection degree | DIN EN 60529, IP66 |
| Emitted interference | EN 61000-6-4:2007 |
| Noise immunity | EN 61000-6-2:2005 |
| Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms |
| Vibration resistance | DIN EN 60068-2-6, 10 g, 10 … 2000 Hz |
| Ambient conditions | |
| Operating temperature | -40 … 55 °C (-40 … 131 °F) |
| Storage temperature | -40 … 70 °C (-40 … 158 °F) |
| Mechanical specifications | |
| Housing material | aluminum |
| Shaft material | stainless steel |
| Mass | approx. 3400 g |
| Rotational speed | max. 6000 min⁻¹ |
| Starting torque | ≤ 5 Ncm |
| Shaft load axial | 60 N |
| Shaft load radial | 80 N |
| Data for Ex-areas application | |
| EC-Type Examination Certificate | ZELM 02 ATEX 0078 X |
| Protection type | II 2G Ex nA IIC T6 Gb; II 2D Ex tD IIC 180 °C Db IP66 |
| Directive conformity | EN 60079-0:2012; EN 60079-1:2007; EN 60079-31:2009 |