RVI70E-021K2A61N-00100 Explosion-Proof Encoder Custom Replacement Solution
Our replacement for the RVI70E-021K2A61N-00100 explosion-proof encoder is specifically developed to mirror the original product in all critical aspects, from size to electrical specifications. Customers can install it directly without adjustment, benefiting from a lead time of around 10 working days. This has enabled industrial partners in Southeast Asia, the Middle East, South America, and Russia to maintain efficient production lines with minimal downtime.
The RVI70E-021K2A61N-00100 encoder is designed to operate securely in potentially explosive environments, making it suitable for hazardous zones. It offers incremental feedback at 100 pulses, ideal for applications requiring reliable yet lower-resolution signal output. The ruggedized enclosure and explosion-proof certification ensure that it maintains safe functionality in challenging conditions. Its durability and consistent accuracy make it a dependable component in safety-critical automation systems.
Replacement model image below.
Dados técnicos
Specification Category | Parâmetro | Detalhes |
---|---|---|
Especificações gerais | Tipo de detecção | amostragem fotoelétrica |
Tipo de dispositivo | Incremental rotary encoder | |
Pulse count | max. 5000 | |
Functional safety related parameters | MTTFₐ (Mean Time To Failure) | 140 a |
L₁₀ (Bearing life) | 1.6 E-9 at 3000 rpm | |
Especificações elétricas | Operating voltage (UB) | 10 … 30 V DC or 5 V DC ± 5% (see "Output circuit" in ordering information) |
No-load supply current (IB) | max. 60 mA | |
Output type | push-pull, incremental or RS 422, incremental (see "Output circuit" in ordering information) | |
Voltage drop (UL) | < 4 V (push-pull, incremental) | |
Load current | max. per channel 35 mA (push-pull, short-circuit protected, reverse polarity protected)max. per channel 20 mA (RS 422, short-circuit protected, reverse polarity protected) | |
Output frequency | max. 200 kHz | |
Rise time | 250 ns | |
Phase position A to B | 90° ± 18° | |
Ciclo de trabalho | 1/2 ± 20% | |
De-energized delay (toff) | 250 ns | |
Conexão | Cable | ∅10.2 mm, Radox 9 × 0.5 mm² |
Conformidade com os padrões | Grau de proteção | DIN EN 60529, IP66DIN EN 60529, IP67 |
Climatic testing | DIN EN 60068-2-30, no moisture condensation | |
Emitted interference | EN IEC 61000-6-4:2019 | |
Noise immunity | EN IEC 61000-6-2:2019 | |
Resistência a choques | DIN EN 60068-2-27: 100 g, 6 ms | |
Resistência à vibração | DIN EN 60068-2-6: 10 g ... 2000 Hz |
Approvals and Certificates
Certification | Detalhes |
---|---|
IECEx approval | Equipment protection level Gb: IECEx ZLM 14.0003XEquipment protection level Db: IECEx ZLM 14.0003X |
ATEX approval | Equipment protection level Gb: ZELM 14 ATEX 0619 XEquipment protection level Db: ZELM 14 ATEX 0619 X |
CCC approval | 2020323414001056 |
Hazardous Location | 19-AVBO-0390 and 19-AVBO-0391 |
KCC approval | (not specified) |
Ambient Conditions
Parâmetro | Detalhes |
---|---|
Temperatura operacional | -40 … 70 °C (-40 … 158 °F) |
Temperatura de armazenamento | -40 … 70 °C (-40 … 158 °F) |
Mechanical Specifications
Parâmetro | Detalhes |
---|---|
Material | Combination 1:housing: anodized aluminumflange: stainless steel 1.4401 / AISI 316shaft: stainless steel 1.4401 / AISI 316Combination 2 (inox):housing: anodized aluminumflange: stainless steel 1.4401 / AISI 316shaft: stainless steel 1.4401 / AISI 316 |
Massa | approx. 1300 g (combination 1)approx. 1500 g (combination 2, anodized) |
Velocidade de rotação | máx. 6000 min-¹ |
Momento de inércia | 400 g·cm² |
Torque inicial | < 5 mN·m |
Shaft load | Axial: 150 NRadial: 110 N |
General Information
Item | Detalhes |
---|---|
Use in hazardous area | see Instruction manuals |