We provide a dedicated custom 1:1 replacement solution for the C-FG40KK-2048G-90G-NG-S encoder, developed specifically to resolve sourcing challenges, legacy equipment maintenance, and discontinued-model issues. This replacement is engineered according to the exact dimensions and performance characteristics of the original encoder. All mounting interfaces, shaft details, output signals, and electrical specifications are reproduced through non-standard customization, ensuring full compatibility with existing installation environments. Because the replacement follows a precise one-to-one configuration, customers can install it immediately without requiring structural modifications, software adjustments, or additional calibration procedures.
Since introducing this tailored replacement service, our customized encoders have been widely adopted across a variety of international markets. Users from the Middle East, Russia, Indonesia, Ukraine, Southeast Asia, and Brazil have successfully commissioned replacements to support critical machinery in steel production, automation lines, processing equipment, and other heavy-duty applications. Customers appreciate both the functional reliability of the customized units and our ability to keep the production cycle at approximately 15 working days, which minimizes downtime and allows maintenance teams to restore equipment operation quickly and efficiently.
Replacement solution image


Technical data
| Parameter | Value |
|---|---|
| Pulse rates | |
| Standard pulse rates | 500, 600, 1000, 1024, 1200, 2000, 2048, 2400, 2500 |
| Special pulse rates | 4000, 4096, 4800, 5000, 8192, 10000, 12000, 16000, 16384, 20000, 25000, 40000, 50000 (further pulse rates according to customer specification) |
| Connection data | |
| Supply voltage | 12 V … 30 V DC (optional: 5 V DC) For UL and CSA Class 2 supplied |
| No load-current | approx. 50 mA at 24 V |
| Outputs | Current limited, short-circuit proof push-pull line driver with integrated impedance adaptation for 30 to 140 Ω lines |
| Pulse height (HTL) | approx. as supply voltage, output saturation voltage < 0.4 V at Iₗ 30 mA |
| Output current | max. 150 mA at 24 V (observe derating) |
| Internal resistance | 75 Ω bei 24 V |
| Slew rate | 200 V/μs with C_L 100 pF |
| Duty cycle | 1:1 ± 3 % for standard pulse rates 1:1 ± 5 % for special pulse rates up to 25000 pulses |
| Square wave displacement 0°, 90° | 90° ± 3 % for standard pulse rates 90° ± 5 % for special pulse rates up to 25000 pulses |
| Max. frequency | 200 kHz, Higher max. frequency on request |
| Special output voltage 5V (TTL) | |
| Pulse height | 5V, RS422-compatible (TIA/EIA-Standard) |
| Supply voltage | 12 … 30 V DC (optional: 5 V DC) For UL and CSA Class 2 supplied |
| Alternative Connection Data (from image(1)_1.png) | |
| Supply voltage | 5 V … 30 V DC For UL and CSA Class 2 supplied |
| No load-current | Approx. 120 mA at 5 V, approx. 50 mA at 24 V |
| Output signals | 2 sinusoidal signals A and B each with inverted signals Reference pulse with inverted signal Signal amplitude 1 V pp / R_L = 120 Ω Error signal and inverted signal Signal amplitude 5V |
| Resolution | 1024 signal periods |
| Duty cycle | 1 ± 0.1 |
| Phase shift A, B | 90° ± 1° |