We provide a complete 1:1 replacement solution for the FG40S-600G-90G-NG heavy-duty incremental encoder, designed specifically for users who face sourcing difficulties or need an alternative to models that are no longer available from the original supplier. Our engineering team recreates all functional and mechanical parameters through non-standard customization, ensuring that the replacement maintains the exact same installation dimensions, shaft configuration, output characteristics, and overall operating behavior. This allows the encoder to be installed directly onto existing equipment without any structural adjustments or control-system modifications. The replacement matches the original in both electrical interface and environmental robustness, making it a true plug-and-play substitute for demanding industrial environments.
Since the release of this customized replacement series, the solution has been adopted by customers across the Middle East, Russia, Indonesia, Brazil, Southeast Asia, Ukraine, and several other regions. Many of these industries operate in harsh and continuous-duty conditions—especially steel plants, rolling mills, heavy machinery lines, and crane systems—where equipment downtime is costly and fast recovery is essential. Users appreciate the reliability of our replacement encoder as well as our significantly shorter production cycle. With a manufacturing lead time maintained at approximately 15 working days, customers are able to restore system operation much faster compared with traditional procurement channels.
Replacement solution image


Technical data
| Parameter | Value |
|---|---|
| Pulse rates | |
| Standard pulse rates | 500, 600, 1000, 1024, 1200, 2000, 2048, 2400, 2500 |
| Special pulse rates | 4000, 4096, 4800, 5000, 8192, 10000, 12000, 16000, 16384, 20000, 25000, 40000, 50000 (further pulse rates according to customer specification) |
| Connection data | |
| Supply voltage | 12 V … 30 V DC (optional: 5 V DC) For UL and CSA Class 2 supplied |
| No load-current | approx. 50 mA at 24 V |
| Outputs | Current limited, short-circuit proof push-pull line driver with integrated impedance adaptation for 30 to 140 Ω lines |
| Pulse height (HTL) | approx. as supply voltage, output saturation voltage < 0.4 V at Iₗ 30 mA |
| Output current | max. 150 mA at 24 V (observe derating) |
| Internal resistance | 75 Ω bei 24 V |
| Slew rate | 200 V/μs with C_L 100 pF |
| Duty cycle | 1:1 ± 3 % for standard pulse rates 1:1 ± 5 % for special pulse rates up to 25000 pulses |
| Square wave displacement 0°, 90° | 90° ± 3 % for standard pulse rates 90° ± 5 % for special pulse rates up to 25000 pulses |
| Max. frequency | 200 kHz, Higher max. frequency on request |
| Special output voltage 5V (TTL) | |
| Pulse height | 5V, RS422-compatible (TIA/EIA-Standard) |
| Supply voltage | 12 … 30 V DC (optional: 5 V DC) For UL and CSA Class 2 supplied |
| Alternative Connection Data (from image(1)_1.png) | |
| Supply voltage | 5 V … 30 V DC For UL and CSA Class 2 supplied |
| No load-current | Approx. 120 mA at 5 V, approx. 50 mA at 24 V |
| Output signals | 2 sinusoidal signals A and B each with inverted signals Reference pulse with inverted signal Signal amplitude 1 V pp / R_L = 120 Ω Error signal and inverted signal Signal amplitude 5V |
| Resolution | 1024 signal periods |
| Duty cycle | 1 ± 0.1 |
| Phase shift A, B | 90° ± 1° |