For the CR66-4096G24KC02 model, we offer a dedicated 1:1 replacement solution designed specifically for parallel absolute encoder applications. This solution focuses on solving real-world problems such as obsolete model risks, procurement bottlenecks and extended supplier delivery times. The replacement encoder is developed by completely reproducing the original product’s housing dimensions, shaft tolerances, mounting interface and electrical output layout. This guarantees full compatibility with existing equipment and supports direct installation without additional mechanical adapters or electrical modifications, creating a smooth and reliable upgrade path.
This solution has already been exported to many international regions, including the Middle East, Russia, Indonesia, Brazil, Southeast Asia and Ukraine. Customers have given highly positive feedback due to the product’s stable signal transmission, strong operating reliability and competitive pricing advantages. Through continuous production optimization, we have established a standard manufacturing cycle of 15 working days, allowing customers to significantly reduce waiting time and keep their production lines running efficiently. The combination of fast delivery, consistent quality and cost-effective performance has made this replacement solution a preferred choice for many industrial users.
Reference Images


Technical data
| Parameter | Value |
|---|---|
| Resolution | 2 to 4096 positions / 360° |
| Measuring range | 2 to 4096 turns |
| Total number of positions | |
| Measurement position deviation | |
| Output frequency* | 30 kHz max. up to 10 Bit / 360°; 10 kHz max. from 11 Bit |
| Disc coding | Gray code |
| Output code, parallel | Gray or Natural Binary |
| Code sense, serial | CW or CCW (Signal input E2) |
| Logic polarity | Positive |
| Memory circuit | Store or not store, signal input E1 |
| Enable circuit (for bus operation) | Active or inactive, (signal input E1) |
| Sensor system | GaAlAs diodes, photo-transistor array |
| Parallel output circuits | A = Open collector Darlington; B = Open collector, TTL compatible; C = Open emitter Darlington; D = Push-pull, Totem-pole |
| Serial output SSI | Differential data output to RS 422 |
| Clock input SSI | Differential (opto-coupler) for data driver to RS 422 |
| Supply voltage range | +11 V to +26 VDC |
| Supply current | Parallel: 90 mA typ. / 120 mA max.; Serial GSI: 130mA typ. / 160mA max. |
| Operating speed | 3000 rpm max. (continuous); 4000 rpm max. (short period) |
| Angular acceleration | 10° rad/s² max. |
| Inertial mass of rotor | ≤ 5 Ncm (8 Ncm - CR 66) |
| Wind-up torque | ≤ 1 Nm (4 Ncm - CR 66) |
| Permissible axial and radial shaft load | 250 N max. |
| Bearing life expectancy | 10⁹ revolutions |
| Operating temperature range | -20°C to +60°C |
| Storage temperature range | -25°C to +70°C |
| Permissible rel. humidity | 85% without condensation |
| Resistance to shock | 200 m/s², 11 ms (DIN IEC 68) |
| Resistance to vibration | 5 Hz..1000 Hz; 100 m/s² (DIN IEC 68) |