GM400.Z33 SSI Penyandi Mutlak Custom Replacement Solution
We offer a professional replacement solution for the GM400.Z33 encoder, manufactured using a 1:1 customization process to replicate all critical aspects of the original Baumer model. With a production cycle reduced to 10–15 working days, we help customers achieve shorter delivery schedules, enabling fast component replacement and reduced downtime in wind power operations. This rapid turnaround offers a clear advantage over extended import lead times.
The GM400.Z33 replacement encoder is engineered for absolute multiturn measurement via SSI interface, applying optical sensing technology for enhanced precision and reliability. Its maximum resolution is 14-bit for singleturn and 16-bit for multiturn measurement, meeting the requirements of wind turbine feedback systems and other industrial automation applications. The encoder is designed with a clamping flange for solid mechanical fixing and supports zero-point setting through electronic adjustment. With its additional features, such as counting direction input and optional incremental output signals, it provides flexible integration into different control systems. Its resistance to magnetic disturbances ensures stability and long-term operation even under harsh electromagnetic conditions.
Replacement model real product photo.

Data Teknis
Electrical Ratings
Parameter | Values |
---|---|
Voltage supply | 10…30 VDC5 VDC ±10 % |
Reverse polarity protection | Yes (10…30 VDC) / No (5 VDC) |
Consumption w/o load | ≤50 mA (24 VDC)≤80 mA (5 VDC) |
Initializing time typ. | 20 ms after power on |
Interface | SSIIncremental A 90° B (optional) |
Function | Multiturn |
Steps per revolution | ≤16384 / 14 bit |
Number of revolutions | ≤65536 / 16 bit |
Absolute accuracy | ±0.025° |
Sensing method | Optical |
Code | Gray or binary |
Code sequence | CW/CCW coded by connection |
Inputs | SSI clock; Control signals UP/DOWN inv. and zero; SSI data outputs RS422 |
Output stages | Diagnostic: 1024, 2048 pulses + invertedIncremental output: 512, 1024, 2048 push-pull |
Interference immunity | EN 61000-6-2 |
Emitted interference | EN 61000-6-4 |
Diagnostic function | Self-diagnosis; Multiturn sensing |
Approval | UL approval / E63076 |
Mechanical Design
Parameter | Values |
---|---|
Size (flange) | ∅58 mm |
Optional |
---|
Stainless steel design |
Corrosion protection for offshore applications |
Parameter Category | Values |
---|---|
Shaft type | α10 design solid shaft |
Flange | Clamping flange |
Protection EN 60529 | IP 54 (without shaft seal)IP 65 (with shaft seal) |
Operating speed | ≤10000 rpm (mechanical)≤6000 rpm (electric) |
Angular acceleration | ≤25000 rad/s² (UB = 0 VDC)≤25000 rad/s² (UB = 10…30 VDC, 5 VDC) |
Starting torque | ≤0.015 Nm (+25 °C, IP 54)≤0.03 Nm (+25 °C, IP 65) |
Rotor moment of inertia | 20 g·cm² |
Admitted shaft load | ≤20 N axial≤40 N radial |
Material | Housing: aluminiumFlange: aluminium |
Suhu pengoperasian | -25…+85 °C-40…+85 °C (optional) |
Relative humidity | 95 % non-condensing |
Resistance | EN 60068-2-6Vibration ≤0.75 mm - 10 - 58 Hz, 10 g - 58 - 2000 HzEN 60068-2-27Shock 200 g, 6 ms |
Weight approx. | 400 g |
Koneksi | Connector M23, 12-pinConnector M12, 8-pinCable 1 m |